BLE RS-232 adapter user manual V1.0
2400
4800
9600
(Default)
19200
38400
57600
115200
230400
460800
921600
?
BIT=
7
8
?
DEFAULT=
Y
DFU=
Y
ECHO=
N
(Default)
Y
?
FLOW=
(Default)
N
Y
?
NAME=
(Default)
BLE232
xx....xx
R
?
PARITY=
2400 bps
4800 bps
9600 bps
19200 bps
38400 bps
57600 bps
115200 bps
230400 bps
460800 bps
921600 bps
Inquire the current baud rate.
7 data bit
8 data bit
Inquire the current data bit
This command is used to restore the default settings and originate a
warm start.
Restore the default settings (e.g. 19200 bps).
The command will re-start the system for 1 second.
Device Firmware Upgrade via PC software. OTA (Over the air) is
available to upgrade the firmware by APP
This command is used to specify whether the adaptor echoes
characters received from the UART back to the DTE/DCE.
Command characters received from the UART are not echoed back to
the DTE/DCE.
Command characters received from the UART are echoed back to the
DTE/DCE.
Inquire the current setting.
This command enable or disable flow control signals (CTS/RTS) of the
UART port. Note, the setting is not affected by DEFAULT.
The command will need 1 second delay.
Disable flow control.
Enable flow control.
Inquire the current setting
This command is used to specify a device name for the adaptor.
You can specify a friendly name using 0 to 9, A to Z, a to z, space and
–, which are all valid characters. Note that "first space or -, last space or
– isn't permitted". The default name is "Serial Adaptor".
Default device name
"xx....xx" is a character string with the length from 2 to 30.
Restore the default settings name="BLE Serial".
Inquire the name of the local adaptor.
This command is used to specify parity bit setting of COM port.
The command will need 200 ms delay.
6
2018.05.22