DIGITIZE 1221 Quick Start Manual - Page 6
Browse online or download pdf Quick Start Manual for Transmitter DIGITIZE 1221. DIGITIZE 1221 9 pages. Radio transmitter option
1221 RADIO TRANSMITTER OPTION MANUAL
1.3
1221 RADIO TRANSMITTER SET UP
After the 1221 Radio Transmitter option is installed on the unit, the operator will access the Set
Up Mode through the front panel keypad. By pressing the SET button, the operator may step
through all available menus. If pressed for over one second, the SET button will auto repeat.
Direct access to the 1221 Radio Transmitter menu is possible by entering the menu number (26),
pressing SET, and then FUNC. If the password has not yet been entered, it must be entered at
this time (default password is 2222).
After pressing 26 SET and entering the password (if needed), the display will read:
The following revolving message will scroll across the bottom of the display:
<<Use numeric keys to change value. Press FUNC to move to the next field Press CLEAR to abort.
Press SET for start transfer.
1.3.1 DAILY TEST BOX NUMBER
The box number (BX #) specified here will be used in the daily test from the SYSTEM 3500
to the Fire Department. The box number can be three to six digits long with a one or two digit
suffix. The protocol of the number must match the Fire Department's receiving equipment
protocol. For example, if the Fire Department accepts the Digitize 99ZN format, and it uses
four-digit box numbers, then the box number entered would be 123499. The 1234 is the box
number, the 99 indicates the daily test zone. Do not enter leading zeros. If the box number
is 123, simply enter 12399, even if with a four-digit box number system.
Use the numeric keys to change the box number value.
CAUTION!: If the Remove Fuse Bypass note appears on the thermal paper tape, be sure
to remove the jumper from position J1 on the configurator card (P/N 400526-0001).
1.3.2 BOX FORMAT
Press FUNC to move to the box format (4-2) field. The rotating messages changes to:
<<Use ↑↓ keys to change value. Use FUNC to move to next field. Use – to move to previous field.
Press CLEAR to END. All changes are accepted when entered.
Use the arrow keys to select the proper box format to match the Fire Department. Selection
includes: 3-1, 3-2, 4-1, 4-2, 5-1, 5-2, 6-1, and 6-2 formats.
NOTE: If 99Z=Y is selected, the '–2' cannot be changed to any other value. For this variable
to be selectable, 99Z=N must be selected.
6
<<Use numeric keys
BX # 888899
DLY=10 Sec 99Z=Y
MAN=Y
Specifications Subject to Change Without Notice
4-2
TEST=12:08