Specifications
Table 6
Device
CWDM-MUX8A
Filter Passband Width
Channel Insertion Loss
Monitor Insertion Loss
CWDM-OADM4-x
Filter Passband Width
CWDM Channel Insertion
Loss
Pass 1550-nm Insertion
Loss
Pass 1310-nm Insertion
Loss
Monitor Insertion Loss
CWDM-OADM1-xxxx
Filter Passband Width
CWDM Channel Insertion
Loss
Pass 1550-nm Insertion
Loss
Pass 1310-nm Insertion
Loss
Monitor Insertion Loss
WDM-1300-1550-S
Pass 1310-nm Insertion
Loss
Pass 1550-nm Insertion
Loss
Cisco CWDM Passive Optical System Installation Note
26
CWDM OADM and Multiplexer/Demultiplexer Module Optical Specifications
Path
Add/Drop
Add/Drop
Network Tx/Rx
Monitor Tx/Rx
Add/Drop
Add/Drop
NETWORK Rx/Tx—PASS Tx/Rx
NETWORK Rx/Tx—PASS Tx/Rx
NETWORK Rx/Tx—MONITOR Tx/Rx
PASS Rx/Tx—MONITOR Tx/Rx
Add/Drop
Add/Drop
NETWORK Rx WEST/EAST—
NETWORK Tx EAST/WEST
NETWORK Rx WEST/EAST—
NETWORK Tx EAST/WEST
NETWORK Tx/Rx WEST/EAST—
TAP Tx/Rx WEST/EAST
Add/Drop
Add/Drop
Value
± 6.0 nm (minimum)
2.2 dB (maximum)
23 dB (maximum
±6.0 nm (minimum)
1.8 dB (maximum)
2.1 dB (maximum)
2.1 dB (maximum)
23 dB (maximum)
±6.0-nm (minimum)
1.5 dB (maximum)
1.5 dB (maximum)
1.7 dB (maximum)
23 dB (maximum)
1.2 dB (maximum)
0.8 dB (maximum)
78-16565-02