Cisco Firepower 4100 Series Maintenance And Upgrade Manual - Page 10

Browse online or download pdf Maintenance And Upgrade Manual for Network Hardware Cisco Firepower 4100 Series. Cisco Firepower 4100 Series 20 pages. Rack-mount and ground the chassis
Also for Cisco Firepower 4100 Series: Product Manual (17 pages), Manual (8 pages), Manual (36 pages), Manual (8 pages), Manual (42 pages), Manual (38 pages)

Cisco Firepower 4100 Series Maintenance And Upgrade Manual

Connect the DC Power Supply Module

Figure 4: Remove the Power Supply Module
If the slot is to remain empty, install a blank faceplate to ensure proper airflow and to keep dust out of the chassis;
otherwise, install another power supply module.
Step 4
To replace a power supply module, hold the power supply module with both hands and slide it into the power supply
module bay.
Step 5
Push in the power supply module gently until you hear the latch engage and it is seated. Verify the power supply module
is operating correctly by checking the power supply module LED. See
power supply module LEDs.
Connect the DC Power Supply Module
Take note of the following warnings:
Warning
Statement 1002 DC Power Supply
When stranded wiring is required, use approved wiring terminations, such as closed-loop or spade-type with
upturned lugs. These terminations should be the appropriate size for the wires and should clamp both the
insulation and conductor.
Maintenance and Upgrade
10
Maintenance and Upgrade
Power Supply Modules
for a description of the