Cisco Firepower 4110 Manual - Page 7
Browse online or download pdf Manual for Network Hardware Cisco Firepower 4110. Cisco Firepower 4110 36 pages. Rack-mount and ground the chassis
Also for Cisco Firepower 4110: Maintenance And Upgrade Manual (20 pages), Manual (26 pages), Manual (8 pages), Manual (42 pages), Getting Started (42 pages)
Overview
11
Front Panel LEDs
The following figure and table describe the Firepower 4100 front panel LEDs.
Figure 6: Front Panel LEDs
1
3
Network module 3
The 10-Gb network module is shown.
Note
Management
• Off—No connection or port is not in use.
• Amber—No link or network failure.
• Green—Link up.
• Green, flashing—Network activity.
SSD
• Off— SSD not present.
• Green—SSD is present; no activity.
• Green, flashing—SSD is active.
• Amber—SSD failure.
• Amber, flashing—Rebuilding, flashes at 1
Hz.
• Amber, flashing—Predictive failure analysis
(PFA) and hot spare; two fast flashes at 4
Hz, pause for 0.5 seconds.
2
Health (SYS)
• Off—System is not booting yet.
• Green, flashing—Power-up diagnostics are
complete and system is booting up.
• Green—The system has passed power-up
diagnostics.
• Amber—Power-up diagnostics has failed.
• Amber, flashing—Alarm; power-up
diagnostics are running.
4
Power
• Off—Input power not detected.
• Green, flashing—Appears only when you
move the power switch from ON to OFF.
System is shutting down and powers off once
shutdown is completed.
• Amber—System is powering up.
• Green—System fully powered up.
• Amber, flashing—Reserved.
Front Panel LEDs
Overview
7