Status LEDs and Buttons
Table 1-2
Front Panel LEDs, Definitions of States (continued)
LED Name
Network link activity
Power supply status
Temperature status
Fan status
System status
Identification
Power button/Power status LED
Cisco UCS Invicta C3124SA Appliance Installation Guide
1-4
State
Off—The Ethernet link is idle.
Green—One or more Ethernet LOM ports are link-active, but there is no activity.
Green, blinking—One or more Ethernet LOM ports are link-active, with activity.
Green—All power supplies are operating normally.
Amber, steady—One or more power supplies are in a degraded operational state.
Amber, blinking—One or more power supplies are in a critical fault state.
Green—The server is operating at normal temperature.
Amber, steady—One or more temperature sensors have exceeded a warning
threshold.
Amber, blinking—One or more temperature sensors have exceeded a critical
threshold.
Green—All fan modules are operating properly.
Amber, steady—One fan module has failed.
Amber, blinking—Critical fault, two or more fan modules have failed.
Green—The server is running in normal operating condition.
Green, blinking—The server is performing system initialization and memory check.
Amber, steady—The server is in a degraded operational state. For example:
Power supply redundancy is lost.
CPUs are mismatched.
At least one CPU is faulty.
At least one DIMM is faulty.
At least one drive in a RAID configuration failed.
Amber, blinking—The server is in a critical fault state. For example:
Boot failed.
Fatal CPU and/or bus error is detected.
Server is in over-temperature condition.
Off—The Identification LED is not in use.
Blue—The Identification LED is activated.
Off—There is no AC power to the server.
Amber—The server is in standby power mode. Power is supplied only to the CIMC
and some motherboard functions.
Green—The server is in main power mode. Power is supplied to all server
components.
Chapter 1
Overview