Acuity Brands HOLOPHANE Utility Series Installation And Maintenance Manual - Page 5

Browse online or download pdf Installation And Maintenance Manual for Lighting Equipment Acuity Brands HOLOPHANE Utility Series. Acuity Brands HOLOPHANE Utility Series 8 pages. Utility series led retrofit kit

Figure 4
Place the "cage" portion back on the housing while threading
2.2.11
the lower portion of the harness into the hole provided in top housing.
Attach the quick-disconnect plastic connector with black and white
wires onto the plastic connector with red and blue wires coming from
the driver. Attach the green ground terminal to the inside of the
housing.
2.2.12
Replace the glass or plastic optic. Orient "street side" on optic
with street side of luminaire. See Figure 5 and Figure 6.
2.2.13
Figure 4 shows the lower reflector assembly and how it will
assemble. Use the two hex bolts referenced in Figure 3 to secure this
assembly. Use the third hex bolt to secure the cable assembly bracket.
Align the main harness cable along the cable assembly bracket with
the top of the white overmold lining up with the top of the bracket. Wire
tie the harness to the cable assembly bracket at the slots.
2.2.14
The next portion of the retrofit is to remove the existing
reflector from the cover portion of the luminaire. Make the final harness
connection to the heat sink LED assembly and place the LED heat sink
assembly into the luminaire on top of the glass or plastic optic as
shown in Figure 5.
NOTE:
There is an orientation to this heat sink assembly. Ensure
the raised boss on the heat sink assembly is pointing to the "street
side" of the luminaire. See Figure 5 for ARUE/JFUE and Figure 6 for
PTUE.
Figure 5
Figure 6
GR1958
2.2.15
Now remove the existing latch and discard this latch and
screws. Replace using the parts included. See Figure 7. Tighten the
screws to the latch to 15-20 in-lbs.
Figure 7
2.2.16
Reconnect the top cover to the optic housing using the hinge
pin and clip originally removed. Close the cover and tighten the latch
screw until the top and bottom latch components meet.
2.2.17
Check to make sure that closing the door assembly with the
new LED driver attached does not pinch any wire assemblies. Return
the luminaire to its mounting position and reconnect the lead wires to
the terminal block. Close and latch the door assembly and energize the
fixture.
GR2668
GR1958
IM-431-A