6. Inverter settings
Different inverter and setting are different. P750V5.0 can control nearly all model inverter. 12V or 24V
accessories power supply. PNP or NPN output. Here is some samples.
a) TECO FM 50 inverter. 12V, PNP output, now it is no longer
available.
Function
Acceleration time
Deceleration time
Freq. Upper limit
Freq. Lower limit
SP1 Frequency
Start/Stop/Control
Multifunction Input
SP2 Frequency
SP3 Frequency
b) TECO L510s inverter. 24V, PNP output.
Location Function Discerptions
Gate Open High Speed
00-03
Alt Run Source
00-05
Main Freq Source
00-06
Alt Freq. Source Select
00-07
Mina & Alt Com
00-12
Max. Frequency
00-14
Acceleration time
00-15
Deceleration time
02-00
Motor rated current
02-01
Motor protect Current
05-02
Gate Open Low Speed
05-03
Gate Close High Speed
05-04
Gate Close Low Speed
P750V5.0 industrial gate motor manual
F
Function Description
F001
Acceleration time
F002
Deceleration time
F006
Max. Frequency
F007
Min. Frequency
F008
Gate Close High Speed
F010
Terminals
F020
Reset Terminal Function
F026
Gate Open Low Speed
F027
Gate Close Low Speed
10
Setting Unit Note
4.0
2.0
60
0
35
1
6
15
15
Setting
Pot
1
1
0
1
60 Hz
3.5-4.0 sec
2.0 sec
3.5A -- P750
6.8A -- P750
15
35
15
Sec.
Sec.
Hz
Hz
Hz
Hz
Hz
Setting
Keypad
1
0
1
0
60 Hz
3.5-4.0 sec
2.0 sec
2.4A -- P550
4.8A -- P550
15
35
15