Acuity Brands Lighting Lithonia Lighting HLF LED Installation Instructions Manual - Page 3
Browse online or download pdf Installation Instructions Manual for Lighting Equipment Acuity Brands Lighting Lithonia Lighting HLF LED. Acuity Brands Lighting Lithonia Lighting HLF LED 7 pages.
Installation Instructions
HLF LED
DELIVERY: Upon receipt of fixture and accessories (packed sepa rately), thoroughly inspect for any freight damage.
All damage should be reported to the delivery carrier. Compare the catalog descrip tion listed on the packing slip with
the fixture label on the inside of the housing to be sure you have received the correct merchandise.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must accept any interference received, including interference
that may cause undesired operation.
HLF INTEGRAL SLIPFITTER (IS) INSTALLATION ON VERTICAL TENONS (+/- 5 °)
Note: Luminaire can be tilted up to 185 degrees (maximum) above horizontal.
Maximum tenon/pole diameter: 2" schedule 40 pipe (2-3/8" OD)
Tools Required:
• 9/64" Allen Wrench
• 3/16" Allen Wrench
• 3/8" Allen Wrench
NOTE: This luminaire is pre-wired with UL listed
supply wire leads. It is not necessary to access
fixture housing to install or wire the luminaire.
1. Remove the two (2) 8-32 splice wire access
cover fasteners from knuckle assembly, remove
the splice access cover, and pull supply wire leads
from knuckle cavity. CAUTION: Do not attempt
to pull additional length from the rotating junction
of the slipfitter. Doing so may damage the wires.
(See figure 2).
2. Slip luminaire knuckle fitter over 2-3/8" Ø pole
tenon and evenly tighten the six (6) 3/8-16 UNC
knuckle tenon set screws to 23-27 ft-lbs, while
maintaining the correct position of the luminaire
(see figure 1).
3. Cut and splice the wires. Recommended cut
length is 6" for wires for ease of splicing and secur-
ing in the knuckle.
4. Make all wiring connections via the supplied wire
leads in accordance with NEC and local codes.
5. Push all fixture and supply wires completely
within the knuckle cavity and replace the splice
access cover, gasket, and two (2) 8-32 splice ac-
cess cover fasteners. Torque the cover fasteners to
18-20 in-lbs.
Lithonia Lighting Outdoor • One Lithonia Way • Conyers, Georgia 30012
Phone: 800-279-8041 • Fax: 770.918.1209 •
© 2011 Acuity Brands Lighting, Inc. All rights reserved.
www.lithonia.com
5 year limited warranty
Part Number: RJ521380 Rev C
Revision Date: 12-4-19