ABB DCS800-S01-0125-05 Firmware Manual - Page 5
Browse online or download pdf Firmware Manual for DC Drives ABB DCS800-S01-0125-05. ABB DCS800-S01-0125-05 20 pages.
Terminal #
Signal
Factory
90...270 V
1
AITAC-
30...90 V
2
AITAC-
8...30 V
3
AITAC-
4
AITAC+
X3:
5
AI1-
6
AI1+
7
AI2-
8
AI2+
9
AI3-
10
AI3+
1
AI4-
2
AI4+
3
0 V
4
+10 V
5
-10 V
X4:
6
0 V
7
AO1
8
AO2
9
IACT
Actual motor current
10
0 V
X5:
1-10
1
DI1
Converter fan ack.
2
DI2
Motor fan ack.
3
DI3
Main contact. ack.
4
DI4
Off2 (coast stop)
X6:
5
DI5
E-Stop
6
DI6
Reset
7
DI7
OnOff1
StartStop
8
DI8
(MainContAck)
9
+24 V
10
0 V
1
DO1
Fans On cmd.
2
DO2
Field excit. On cmd.
3
DO3
Main contact. On cmd.
4
DO4
X7:
5
DO5
6
DO6
7
DO7
8
0 V
1
X96:
DO8 Relay
Main Contact. On
2
Factory macro.
Resets all
parameters to
default values.
Description
Table 1a: Macro Configurations: The analog and digital inputs and outputs shown in this table are
automatically configured when you implement the macro identified in the top row.
**In revisions prior to 2.6, AI-2 was set to torque limit. AI-2 is unused in rev. 2.6 and higher. If
"torque limit" feature is required, use the new "Torque Limit" macro instead.
***In revisions prior to 2.6, DI-4 controlled "speed reference select." DI-2 controls this selection in
rev. 2.6 and above, along with selection of hand or auto mode. In "hand" mode, speed select is via
AI-1; in "auto" mode, speed select is via parameter 23.01.
DCS800 Firmware manual supplement for North America (rev. 2.60, 2.70) Rev. b
Standard
Manual / Const Spd
-
-
-
-
-
-
-
-
-
Speed Reference
Speed Reference
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Motor speed
-
Arm. voltage act.
Actual motor current
Actual motor current
Actual motor current
-
-
-
-
Jog1
Jog2
External fault
KpS & TiS to Set1 or
External alarm
E-Stop
Reset
OnOff1
StartStop
Off1 Stop pulse NC
(MainContAck)
-
-
-
-
ReadyRun
ReadyRef (running)
ReadyRef (running)
Fault or alarm
-
Zero speed
-
Above limit
-
-
-
-
-
-
Main Contact. On
Main Contact. On
Drive turns on with
Speed is
maintained input.
controlled by AI-1,
Motion is
but if Jog1 or Jog2
commanded with
is set, speed is set
RUN, JOG1, or
to 23.02 or 23.03.
JOG2. Run speed
DI-4 switches to
is set with AI-1.
another set of
tuning values to
run a different
motor. Control is
3-wire.
*Jog inputs do
not initiate
motion, only
change speed.
Hand / Auto
-
-
-
-
-
-
-
-
Speed Reference
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Motor speed
Motor speed
Actual motor current
Actual motor current
-
-
-
-
StartStop
Jog1*
(MainContAck)
HandAuto, Speed ref
Jog2*
select
Direction
Direction
-
Set2 (24.29)
E-Stop
E-Stop
Reset
Reset
On Start pulse
OnOff1
-
-
-
-
-
ReadyOn
ReadyOn
ReadyRef (running)
Tripped (fault)
Tripped (fault)
Zero speed
Zero speed
Above limit
Above limit
-
-
-
-
-
-
Main Contact. On
DI-2 switches
between Hand
(Local I/O) and
Auto
(MainCtrlWord)
mode, and also
switches speed
reference. In
"hand" mode,
speed select is via
AI-1; in "auto"
mode, it is via
parameter 23.01.
Fieldbus module
is required.
Manual control is
2-wire.
Hand / Motor Pot
Motor Pot
-
-
-
-
-
-
-
-
Speed Reference
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Motor speed
Motor speed
Actual motor current
Arm. voltage act.
Actual motor current
Actual motor current
-
-
-
-
Motor pot up
Direction
Motor pot down
Motor pot up
Direction
Motor pot down
Speed ref. select
(Off=MotorPot;
Motor pot minimum
On=AI1)
E-Stop
E-Stop
Reset
Reset
On Start pulse
OnOff1
StartStop
Off1 Stop pulse NC
(MainContAck)
-
-
-
-
ReadyOn
ReadyRun
ReadyRef (running)
Above limit
Tripped (fault)
Fault or alarm
Zero speed
Zero speed
Above limit
At Setpoint
-
-
-
-
-
-
Main Contact. On
Main Contact. On
DI-4 switches
Speed is always
between Motor
controlled through
Pot and AI-1 to
the motor pot up
select reference
and down inputs.
speed. Control is
Motor pot
3-wire.
minimum speed
can be released
by setting DI-4 to
allow motor pot
down to reduce
speed to zero.
Control is 2-wire.
5/30/2008
5