Browse online or download pdf Instructions Manual for DC Drives ABB Dodge SCXT105. ABB Dodge SCXT105 16 pages. Screw conveyor and hydroil screw conveyor drive
When Placing the Reducer Into Service:
1.
Assemble the vent plug into the proper hole.
2.
Clean the shaft extensions with petroleum solvents.
3.
Fill the unit to the proper oil level using a recommended
lubricant. VCI oil will not affect the new lubricant.
4.
Follow the installation instructions provided in this manual.
Table 4 - Quantity of VIC #105 Oil
Case Size
(H)SCXT105
(H)SCXT205
(H)SCXT305A
(H)SCXT405A
(H)SCXT505A
(H)SCXT605
(H)SCXT705
VCI #105 & #10 are interchangeable.
VCI #105 is more readily available.
Quarts or Liters
.1
.1
.1
.2
.3
.4
.5
5