Argus Optical Light Source User Manual - Page 5
Browse online or download pdf User Manual for Test Equipment Argus Optical Light Source. Argus Optical Light Source 14 pages. Dual-wavelength laser source
4 Specifications
Optical Specifications
Output Wavelength( (nm)
Laser
Spectral Width
Stability: Short Term (15 minutes)
Stability: Long Term (5 hours)
Power
Frequency
Connector
Power Supply
General Specifications
Operation Temperature
Storage Temperature
Humidity
Size (H×W×D)
Weight
NOTE: Please be aware that we will not be responsible for the damage caused by
customer's improper usage of AC power supply, especially when the instrument is working
by internal batteries. The working hours of instrument might show a difference under a
different circumstances and batteries status.
1310 nm, 1490 nm, 1550 nm, 1625 nm (± 20 nm)
Class 1
5 nm
1310 nm < ± 0.05 dB
1490 nm < ± 0.10 dB
1550 nm < ± 0.05 dB
1625 nm < ± 0.10 dB
1310 nm < ± 0.10 dB
1490 nm < ± 0.20 dB
1550 nm < ± 0.10 dB
1625 nm < ± 0.20 dB
-5.0 dBm ± 0.5 dB
270 Hz, 1 kHz, 2 kHz
SC/APC with dust protection and protection
against loss
2x Ni-MH AA (2500 mAh), AC/DC charger
-10 °C ~ +50 °C
-20 °C ~ +70 °C
< 90 %
160 mm × 76 mm × 45 mm
about 270 g (including batteries)
4 Specifications
5