3.3
Operating Temperature: 0° to 50°C (32° to 122°F)
Storage Temperature: -30° to 80°C (-22° to 176°F)
Operating Relative Humidity:
10° to 30° C: 85 ± 5% RH (without condensation)
40° to 50° C: 45 ± 5% RH (without condensation)
Influence of Temperature: < 0.2% per °C
Altitude: Non-operating: 0 to 12,000m
3.4
Electrical: Double insulation or reinforced insulation between the primary
or secondary and the outer case of the handle per EN 61010-2-032.
600V, CAT III, Pollution Degree: 2
Electromagnetic Compatibility:
EN 50081-1 Class B
EN 50082-2 Electrostatic discharge IEC 1000-4-2
*Specifications are subject to change without notice
AC/DC Current Oscilloscope Probe Model SL261
Find Quality Products Online at:
Environmental Specifications
Operating: 0 to 2000m
Safety Specifications
E192383
Radiated Field IEC 1000-4-3
Fast Transients IEC 1000-4-4
Magnetic Field at 50/60 Hz IEC 1000-4-8