ECI CabLite ECO 5000K Installation Manual - Page 13

Browse online or download pdf Installation Manual for Light Fixture ECI CabLite ECO 5000K. ECI CabLite ECO 5000K 14 pages.

Cablite ECO Installation Manual Rev 4.0
The EMERGENCY lights are connected through a second 8' cable as shown in Figure 9. There should
be two and only two downlights connected for emergency. Connecting more than two will shorten the
emergency lighting time.
With all downlights connected, remove the plastic cover from the POS terminal of the battery and connect
RED wire from control board to battery POS terminal. The EMERGENCY downlights should light at
this time.
Apply AC power to CabLite system. All downlights should light. Adjust the brightness of the
downlights through the potentiometer on the control board. See Figure 3 - CabLite ECO Emergency
Board.
When complete replace cover.
Allow 24 hours for battery to fully charge
Electronic Controls, Inc.
7073 North Atlantic Ave. Cape Canaveral, FL 32920
800-633-9788
www.eciamerica.com
P a g e
| 13