Fireplace Installation
Option #3 - Hardwire
1.
Wire a dedicated, properly
fused circuit with 120 Volt,
15 Amp rating. Allow up to
eight (8) feet of service cable
for connecting power supply
to junction box on fireplace
when installing after finishing
wall.
CAUTION: Use two
conductor, non-metallic sheath
cable with ground wire (3
wires total) for the incoming
power supply on fireplace
inserts. use appropriate wire
to meet local and national
electrical codes for rated power
consumption.
Figure 2
2.
remove the outer jacket and
strip the individual conductor
from the end.
3.
Loosen the screw securing
the junction box cover and
remove the cover.
4.
Take the cables out from the
junction box, loosen the two
wire twist nuts and remove
the cord set (Figure 2).
5.
Route the power supply wire
through the knockout on
supplied alternative junction
box cover and secure with
a wire clamp (not supplied)
(Figure 3).
6.
Connect the black wire (live)
from the unit to the black wire
from power supply (Figure 3).
Figure 3
9