Eckerle Gotec SP32/01 Technical Information - Page 5

Browse online or download pdf Technical Information for Water Pump Eckerle Gotec SP32/01. Eckerle Gotec SP32/01 8 pages.

Eckerle Gotec SP32/01 Technical Information
6. Startup Procedure
After the pipe connections are installed the following rules must be taken
under consideration:
- Plug main power supply (position H) into socket. (230V/50-60Hz)
- LCD display (position F) at the housing lights up by showing # 8.
- Close emergency shut-down valve (position J) to the appliance.
- Press start button (position G) briefly, pump starts and keeps running
on automatically.
- After reaching the upper switching level the suction pump switches off
automatically.
- Open emergency shut-down valve (position J) to the consuming
device.
- Consumer (position L) (e.g. stove, oil burner) take into operation.
Note:
In case of long runs of suction pipe or use of larger diameter
pipe, we recommend priming the oil with a hand pump prior to the first
startup procedure in order to avoid a dry running operation of the pump
unit. Dry running operation of the pump unit is electronically limited to 5
min., afterwards the pump switches off automatically. After examination
of the intake on tightness the starting procedure must be repeated.
7. LCD-Display:
The SP32-01 is equipped with an LCD-display which indicates the res-
pective operating condition.
Display:
0. Oil reservoir is empty (e.g. after power failure)
1. Float is in the range oil reserve (close to empty)
2. Float is the range of switching on level
3. Float achieved upper switching off level (pump has switched off)
4. If the pump could not suck in oil (pump tank is empty) a breakdown
disconnection takes place after approx. 5min.
5. If the pump did not reach level (2.) after 20min.
6. Safety float in the oil catch pan is activated. The safety pan is filled
with oil.
7. Temperature sensor switches the pump off automatically with 60°C
ambient temperature. (Detected inside the SP32-01), e.g. during
overloading/overheating of the pump unit.
8. SP32-01 is under electrical tension
8. Maintanance
Before starting the maintenance work and dismounting the grey coloured
plastic cover (position E), always pull the main power supply plug! Ra-
pid-action valves (position J) close. Maintenance of the SP32-01 limits
itself only to the annual cleaning of the inserted fine filter (white plastic
filter cartridge located in front of the electromagnetic piston pump. The
filter can be un-/re-screwed without tool by means of a coin.
9. Possible malfunctions and breakdown causes
The pump is additionally monitored over several control parameters. At
breakdown disconnection the following examinations at the intire system
and at the SP32-01 are to be made:
- Is electrical tension present and the LCD display shines?
LCD-display - off - Check fuse and replace if necessary
- Is oil present in the fuel oil tank? – Possible Lack of oil?
LCD-display 4 or 5
- Is the intake pipe tightened firmly? LCD-display 4 or 5
- Is the suction filter clogged? LCD-display 4 or 5
- Is the oil security pan filled? - Leakage or overflow - LCD-display 6
- Is the ambient temperature of the SP32-01 higher than 60°C?
LCD-display 7
- Is the oil reservoir of the pump empty, i.g. power failure? LCD-display 0
- Is the flow rate of the piston pump built inside still sufficient?
LCD-display 4 or 5

10. Warranty

The warranty period amounts to two years after installation date of the
pump system. With a report on the defective equipment, plus proof of
purchase or installation (delivery note or copy invoice) is to be sent in for
warranty examination of the suppliers.
11. Transportation reference
Prior to the dispatch of used devices they have to be emptied comple-
tely! Transport damages by fuel oil leakage will be at the cost of the
sender!
12. Performance Diagram
28
26
24
22
20
18
16
14
12
10
8
6
4
2
0
0
1
Examples:
With a suction height of 4m and a horizontal distance of 40m the flow
rate will be approx. 12l/h.
or:
With a suction height of 4m and a horizontal distance of 10m the flow
rate will be approx. 18l/h.
- 5 -
GB
Flow rate SP32-01
2
3
4
5
6
Suction height [m]
10m
20m
30m
40m
7
8