Lamp replacement (Continued)
Used Lamps
This projector's lamps contain trace amounts of environmentally harmful inorganic
mercury. Be careful not to break used lamps, and dispose of them in accordance with
local regulations.
Lens and main unit cleaning
WARNING
• Request cleaning and maintenance of a ceiling-mounted unit from your projector dealership.
Attempting to clean/replace the lamp at a high site by yourself may cause you to drop
down, thus resulting in injury.
■ Lens cleaning
• Clean the lens with a commercially available blower and/or
lens cleaner.
• The lens is easily scratched, so do not rub it with hard objects,
or strike it.
■ Main unit cleaning
• Clean the main unit after unplugging the power cord.
• Wipe dirt off the main unit gently with a soft cloth.
• Do not wipe the main unit with a damp cloth. Doing
so may allow water to get inside, resulting in an
electric shock or failure.
• Do not use benzene, thinner and the like as they may
deform or discolor the unit or damage the paint
surface.
• When using a chemically treated cloth, follow the
precautions included with the cloth.
40
Others
Trouble indications
The indicator lights inform you of internal abnormalities.
No power
TEMP
FAN
LAMP
⇒ Problem with projector
• Unplug the power cord, and contact your dealer.
(Off)
Lamp went out during use, or won't come on
TEMP
FAN
LAMP
⇒ Lamp temperature is high so that it is difficult to turn on, the lifetime of
the lamp has ended or the projector is malfunctioning.
(Red lit)
• Unplug the power cord and wait for a short while, then turn the power back on.
• If a lamp burns out, replace it with a new one.
(Red lit)
❈ After approx. one minute of abnormal display, the projector returns to
the standby state waiting for internal cool down.
Power went out during use
TEMP
LAMP
FAN
⇒ Internal overheating, or the outside temperature is too high.
(Red lit or flashing)
• Place the projector so that the air intake and exhaust are not blocked.
(Green lit)
• Unplug the power cord and wait for a short while, then turn the power back on.
❈ The
icon will appear before the power goes out.
Or (Orange lit)
❈ After approx. one minute of abnormal display, the projector returns to
the standby state waiting for internal cool down.
(Red lit)
Power went out during use
TEMP
LAMP
FAN
⇒ Problem with internal cooling fan.
• Unplug the power cord, and contact your dealer.
(Red lit or flashing)
❈ The
icon will appear before the power goes out.
❈ After approx. one minute of abnormal display, the projector returns to
Or
the standby state waiting for internal cool down.
(Orange lit)
(Red lit)
Power went out during use, or power won't come on
TEMP
LAMP
FAN
⇒ The lamp cover is not properly attached.
• Unplug the power cord, and reattach the lamp cover.
(Orange
❈ After approx. one minute of abnormal display, the projector returns to
flashing)
the standby state waiting for internal cool down.
(Red lit)
Power went out during use
TEMP
LAMP
FAN
⇒ Problem inside the projector.
(Green lit
• Unplug the power cord and wait for a short while, then turn the power back on.
(Green lit
or Off)
(Green
• If the above action will not clear the problem, unplug the power cord,
or Off)
flashing)
and contact your dealer.
(Red lit)
❈ After approx. one minute of abnormal display, the projector returns to
the standby state waiting for internal cool down.
TDP-SC35
Power went out during use
TEMP
⇒ Camera is not correctly connected.
LAMP
FAN
• Disconnect the power plug and check the connection with the camera.
❈ The
icon will appear before the power goes out.
(Green lit)
❈ After approx. one minute of abnormal display, the projector returns to
the standby state waiting for internal cool down.
(Red lit)
PRECAUTION
• Make sure to unplug the power cord if something goes wrong.
p.39