Operation using Control Panel - CFCH
Switch on electrical supply to the fan heater and the electronic
control panel. When all units are powered up and there is a
connection between the controller and the master unit, an LED
will turn on in the controller to indicate the units are functioning.
Refer to the CFCH instruction leaflet on the operation of the
electronic control panel.
Delayed Shutdown
Door Switch (3min Runback): By wiring in a normally open contact
to the door switch connections shown in Fig. 7, the folowing
operation is achieved:
•
Up to 1 minute after contact closed, unit runs at set
condition.
•
Between 1 & 2 minutes. unit runs half & half settings.
•
Between 2 & 3 minutes. unit runs fan only settings.
•
Over 3 minutes. unit enters stand-by mode.
PIR Sensor (45min Runback): By changing the PCB mounted
links shown in Fig. 7 the runback timer will operate as follows:
•
Up to 15 minutes after contact closed, unit runs at set
condition.
•
Between 15 & 30 minutes. unit runs half & half settings.
•
Between 30 & 45 minutes. unit runs fan only settings.
•
Over 45 minutes. unit enters stand-by mode.
Modular Linking
A number of fan heaters can be connected together in a 'daisy
chain' fashion. A total of ten units can be controlled from a single
electronic control panel. The required connections can be made
in a daisy chain fashion as shown in Fig. 9. (References shown
below).
ECP - Electronic Control Panel
MU - Master Unit
SU
- Slave Unit
MLC - Modular Linking Cable
CPC - Control Panel Cable
To make these connections remove one of the small knock-outs
and feed an appropriate LAN cable (not supplied) to the BUS
OUT control socket ('D' in Fig. 9) of the Master Unit. Fix this cable
in the back panel using suitable cable gland (not supplied).
Continue this process for all linked heaters. Replace the control
housing of each heater and power up all units. Ensure that all
control settings function correctly.
Thermal Safety Cut-out
The power supply to the heating elements will be interrupted if
one or a combination of the following abnormal events occurs:
1.
Air inlet or outlet grilles are obstructed.
2.
Internal ventilation is impaired due to build up of dust and
fluff.
3.
Blower unit stalls.
Note: Before re-setting the cut-out, the reason for activation must
be determined and corrective action taken.
To reset the thermal safety cut-out, access reset button as shown
in Fig. 6 and push in direction of arrow.
Maintenance
WARNING: Disconnect electrical supply to all connected units
prior to carrying out maintenance.
Optimum performance and long service from this product will
only be realised if regular maintenance is carried out. Dimplex
recommends regular checks dependant on normal use or more
frequent checks where the unit is installed in arduous conditions
or used continually for more than 10 hours per day.
Standard Maintenance
Where the product is subject to use not exceeding 10 hours
per day:
Every 3 months the fan wheels, impellors, heating elements, air
inlet and outlet grilles should be cleaned, removing dust and
debris with a suitable soft brush.
Every 12 months all moving parts should be checked for free
running with appropriate remedy/adjustment made where
necessary.
Extended Maintenance
Where the product is subject to arduous conditions or is used
continually for more than 10 hours per day:
Each month the fan wheels, impellors, heating elements and
air inlet and outlet grilles should be checked and cleaned,
removing dust and debris with a suitable soft brush.
Every 6 months all moving parts should be checked for free
running with appropriate remedy/adjustment made where
necessary.
Recycling
For electrical products sold within the European Community.
At the end of the electrical products useful life it should
not be disposed of with household waste. Please
recycle where facilities exist. Check with your Local
Authority or retailer for recycling advice in your country.
Cleaning
WARNING: DISCONNECT SUPPLY before carrying out
maintenance.
External appearance can be maintained by wiping occasionally
with a damp cloth. For stain removal, a weak soap solution can
be applied with a cloth and the surface wiped dry. Care must be
taken to avoid any moisture ingress into the product.
After Sales Service
Your product is guaranteed for one year from the date of purchase.
Within this period, we undertake to repair or exchange this product
free of charge (excluding element & subject to availability)
provided it has been installed and operated in accordance with
these instructions.
Your rights under this guarantee are additional to your statutory
rights, which in turn are not affected by this guarantee.
Should you require after sales information or assistance with
this product please go to www.dimplex.co.uk where you will
find our self help guide by clicking on "After Sales" or ring our
helpdesk on 0845 600 5111 (UK) or 01 842 4833 (R.O.I.) .
Spare parts are also available on the website
www.dimplex.co.uk
Please retain your receipt as proof of purchase.
Tel: +44 (0)191 490 1547
Fax: +44 (0)191 477 5371
Email:
Website:
www.heattracing.co.uk
www.thorneanderrick.co.uk