Cruise N Comfort MES 12 s Installation & Operating Instructions Manual
Browse online or download pdf Installation & Operating Instructions Manual for Air Conditioner Cruise N Comfort MES 12 s. Cruise N Comfort MES 12 s 7 pages. 12volt marine air conditioners
MES 12/24 L/s 12Volt Marine Air Conditioners
Installation
1. Locate the area where the unit will be mounted and double check
that there are NO obstructions. Make sure that the location allows
for the cold air to return to the units evaporator.
2. Install the A/C control unit in a convenient location. Plug Control
Unit connector into A/C unit receptacle . fig.1
3. Connect ball valve and male threaded nipple to thru-hull pickup
GROCO 34 STH500W 1/2". Use teflon tape on fittings to ensure a
water tight seal. fig.2
4. Find a location under the hull in the transom area to mount the thru-
hull pickup. Make sure the fitting has the grate area facing forward
toward the bow and that the fitting will always be in the water when
the boat is underway. Note: Before drilling be certain there are no
obstructions. Install and seal with marine underwater sealant/glue.
fig.3
5. Find a suitable location for the thru-hull water dump. fig.4 Install
and seal with marine underwater sealant/glue. Remember to install
at least 1 foot above the water line. Thru-hull water dump. fig.5
6. 6. Find a suitable location to install the water pump (under the water
line is recommended). Attach strainer to water pump per
manufacture instructions fig.6 . Run the 14 gauge power wires from
the unit to the water pump. The (RED) wire is the positive and the
(BLACK) is the negative power to the pump. These are 14 gauge
wires, and should be crimped with waterproof connectors to the
pump connector. Connect the pump connector to A/C unit. fig.8 The
water pump is required to flow 3 to 4 gallons per minute. The
current draw of the pump should not exceed 5 amps.