Aeon Labs Aeotec G2 Installation Instructions - Page 2
Browse online or download pdf Installation Instructions for Switch Aeon Labs Aeotec G2. Aeon Labs Aeotec G2 2 pages. Micro double switch micro double smart energy switch
Continued
Turning On/Off the Micro Double Smart Energy Switch G2
Use any of the following methods to allow power through, or cut power
from, the Micro Double Smart Energy Switch G2.
• Through the used of Z-Wave commands built into Z-Wave certified
controllers and gateways. (The specific Z-Wave commands supporting this
Multi Channel Command Class, and Scene Activation Command Class)
Please consult the operation manual for these controllers for specific
instructions on controlling the Micro Double Smart Energy Switch G2.
Pressing the button on the Micro Double Smart Energy Switch G2 will
•
toggle power flow (on/off) through the Micro Double Smart Energy Switch G2.
Change Mode on the External Switch/Button
Control
•
The Aeotec Micro Double Smart Energy Switch G2 is set to be
controlled via 2-state(flip/flop) external wall switch by default. Pushing
and holding the button 6 seconds on the Micro Double Smart Energy
Switch G2 will swap between this default mode and the momentary
push button external wall switch mode.
• Through the usage of Z-Wave command built into Z-Wave certified
controllers and gateways. (The specific Z-Wave command supporting
this funtion is Configuration Command Class) Please consult the
operation manual for these controllers for specific instructions on
changing external wall switch mode of the Aeotec Micro Double Smart
Energy Switch G2.
Monitoring Energy Consumption
The Aeotec Micro Double Smart Energy Swtich G2 can report total wattage
energy usage or kWh energy usage to a Z-Wave gateway or controller
when requested. If this function is supported by the gateway/controller,
the energy consumption will be displayed in the user interface of the
gateway/controller. (The specific Z-Wave commands supporting energy
monitoring are the Meter Command Class. Automatic reports are sent
to association group 1, which is setup via the Association Command
Class.) Please consult the operation manual for these gateways/controllers
for specific instructions on monitoring the Micro Double Smart Energy Switch G2 .
Note: The Micro Double Switch G2 (without the words "Smart Energy")
does not have the ability to monitor energy consumption.
Technical Specifications
•
USA:
120V 60Hz input, 600W of each way or 5A max of each way output.
•
EU/AU/IN/BR/CN:
230V 50Hz input, 1150W of each way or 5A max of each way output.
Warranty
Aeotec warrants to the original purchaser of Products that for the
Warranty Period (as defined below), the Products will be free from
material defects in materials and workmanship. The foregoing warranty
is subject to the proper installation, operation and maintenance of the
Products in accordance with installation instructions and the operating
manual supplied to Customer. Warranty claims must be made by
Customer in writing within thirty (30) days of the manifestation of a
problem. Aeotec' sole obligation under the foregoing warranty is, at
Aeotec' option, to repair, replace or correct any such defect that was
present at the time of delivery, or to remove the Products and to refund
the purchase price to Customer.
The "Warranty Period" begins on the date the Products is delivered and
continues for 12 months.
Any repairs under this warranty must be conducted by an authorized
Aeotec service representative and under Aeotec' RMA policy. Any
repairs conducted by unauthorized persons shall void this warranty.
Excluded from the warranty are problems due to accidents, acts of God,
civil or military authority, civil disturbance, war, strikes, fires, other
catastrophes, misuse, misapplication, storage damage, negligence,
electrical power problems, or modification to the Products or its
components.
Aeotec does not authorize any person or party to assume or create for it
any other obligation or liability in connection with the Products except as
set forth herein.
Aeotec will pass on to Customer all manufacturers' Material warranties
to the extent that they are transferable, but will not independently
warrant any Material.
Customer must prepay shipping and transportation charges for returned
Products, and insure the shipment or accept the risk of loss or damage
during such shipment and transportation. Aeotec will ship the repaired or
replacement products to Customer freight prepaid.
Customer shall indemnify, defend, and hold Aeotec and Aeotec'
affiliates, shareholders, directors, officers, employees, contractors,
agents and other representatives harmless from all demands, claims,
actions, causes of action, proceedings, suits, assessments, losses,
damages, liabilities, settlements, judgments, fines, penalties, interest,
costs and expenses (including fees and disbursements of counsel) of
every kind (i) based upon personal injury or death or injury to property to
the extent any of the foregoing is proximately caused either by a
defective product (including strict liability in tort) or by the negligent or
willful acts or omissions of Customer or its officers, employees,
subcontractors or agents, and/or (ii) arising from or relating to any actual
or alleged infringement or misappropriation of any patent, trademark,
mask work, copyright, trade secret or any actual or alleged violation of
any other intellectual property rights arising from or in connection with
the products, except to the extent that such infringement exists as a
result of Aeotec' manufacturing processes.
IN NO EVENT SHALL AEOTEC BE LIABLE FOR ANY INDIRECT,
INCIDENTAL,
PUNITIVE,
SPECIAL
OR
CONSEQUENTIAL
DAMAGES, OR DAMAGES FOR LOSS OF PROFITS, REVENUE, OR
USE INCURRED BY CUSTOMER OR ANY THIRD PARTY, WHETHER
IN AN ACTION IN CONTRACT, OR TORT, OR OTHERWISE EVEN IF
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. AEOTEC'S
LIABILITY AND CUSTOMER'S EXCLUSIVE REMEDY FOR ANY
CAUSE OF ACTION ARISING IN CONNECTION WITH THIS
AGREEMENT OR THE SALE OR USE OF THE PRODUCTS,
WHETHER BASED ON NEGLIGENCE, STRICT LIABILITY, BREACH
OF WARRANTY, BREACH OF AGREEMENT, OR EQUITABLE
PRINCIPLES, IS EXPRESSLY LIMITED TO, AT AEOTEC'S OPTION,
REPLACEMENT OF, OR REPAYMENT OF THE PURCHASE PRICE
FOR THAT PORTION OF PRODUCTS WITH RESPECT TO WHICH
DAMAGES ARE CLAIMED. ALL CLAIMS OF ANY KIND ARISING IN
CONNECTION WITH THIS AGREEMENT OR THE SALE OR USE OF
PRODUCTS SHALL BE DEEMED WAIVED UNLESS MADE IN
WRITING WITHIN THIRTY (30) DAYS FROM AEOTEC'S DELIVERY,
OR THE DATE FIXED FOR DELIVERY IN THE EVENT OF NONDELIV-
ERY.
THE INDEMNITY AND WARRANTY IN ABOVE ARE EXCLUSIVE AND
IN LIEU OF ALL OTHER INDEMNITIES OR WARRANTIES, WHETHER
EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES
OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE.
FCC NOTICE (For USA):
THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR
TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS
TO THIS EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE
USER'S AUTHORITY TO OPERATE THE EQUIPMENT.
STORE INDOORS WHEN NOT IN USE. SUITABLE FOR DRY
LOCATIONS. DO NOT IMMERSE IN WATER. NOT FOR USE WHERE
DIRECTLY EXPOSED TO WATER.
This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions:
1. This device may not cause harmful interference, and
2.This device must accept any interference received, including
interference that may cause undesired operation. This equipment has
been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communica-
tions. However, there is no guarantee that interference will not occur in
a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
•Consult the dealer or an experienced radio/TV technician for help.
UL NOTICE (For USA):
1. Install only in a UL Listed junction box sized 3X2X2.75 inch
(75X50X70mm) or larger,minimum Volume 14 in (230 cm )
3
2. Use Copper Conductors Only.
3. CAUTION - Risk of Electric Shock - More than one disconnect switch
may be required to de - energize the equipment before servicing.
4. WARNING - This device shall not be used in combination with a wall
switch controlling a receptacle.
Warning:
Do not dispose of electrical appliances as unsorted municipal waste,
use separate collection facilities.
Contact your local government for information regarding the collection
systems available.
Certifications (regional):
3