DINA DN3PD1 Original Instruction Manual - Page 6

Browse online or download pdf Original Instruction Manual for Industrial Equipment DINA DN3PD1. DINA DN3PD1 20 pages. Speed monitoring for one and three phases motors without sensor system
Also for DINA DN3PD1: Temporary Instruction Manual (8 pages)

DINA DN3PD1 Original Instruction Manual
DN3PD1

Intended Use

1
Intended Use
Safety switchgear to monitor the speed of three-phase and single-phase motors without sensor.
Two speed thresholds are possible: minimum speed and maximum speed.
The unit meets Cat. 4/ PL e acc. to ISO 13849-1, SIL (CL) 3 acc. to IEC 62061 and IEC 61508.
Usage in safety current circuit according to VDE 0113 T.1

Approvals

Safety parameters

The unit meets Cat. 4/ PL e and SIL (CL) 3.
Parameter
PFH
MTTF
d
DC
avg
table 1-1: Safety parameters

Ordering data

Speed monitoring, sensorless
6
Value
1,56 E-09 1/h
553 a
95%
Description
0-600Hz, 2 contact outputs,
start-up monitoring
Note
1,6 % von SIL 3
HIGH
(HIGH)
Type
ID-No.:
DN3PD1
33PD02
18-09-27 / 33pd02-V0743