ADJUSTMENT
ADJUSTMENTS REQUIRED WHEN REPAIRING OR REPLACING EACH ASSY
3D Y/C ASSY
1) (Procedure 9)
White balance adjustment
(if white balance is deviated)
ANALOG VIDEO ASSY
1) (Procedure 1)
Blanking pulse width adjustment
(VBLK, HBLK)
2) (Procedure 9)
White balance adjustment
CONTROL ASSY
1) (Procedure2)
VCO control voltage adjustment
2) (Procedure 3)
Vertical sync freerunning frequency
adjustment
3) (Procedure 8)
Factory data setting (At ASSY replacement)
(Read the preset data before replacing
ASSY)
4) (Procedure 9)
White balance adjustment
(if white balance is deviated)
MAIN POWER ASSY
1) (Procedure 4)
VADR voltage (60V) adjustment
VSUS voltage (170V) adjustment
VOFS voltage (140V) adjustment
3D Y/C ASSY
X DRIVE (B) ASSY
ANALOG VIDEO ASSY
CONTROL ASSY
DIGITAL VIDEO ASSY
9
X DRIVE ASSY, Y DRIVE ASSY
1) (Procedure 5)
2) (Procedure 7)
3) (Procedure 9)
DIGITAL VIDEO ASSY
1) (Procedure 6)
2) (Procedure 7)
3) (Procedure 9)
PDP PANEL ASSY
1) (Procedure 4)
2) (Procedure 5)
3)
4) (Procedure 7)
5) (Procedure 9)
X DRIVE (A) ASSY
MAIN POWER ASSY
Y DRIVE (B) ASSY
PDP-V402
VRN voltage adjustment
VH voltage adjustment
Sustain pulse waveform adjustment
(X PSUS, Y PSUS)
White balance adjustment
(if white balance is deviated)
DIP SW setting of the pulse value
Sustain pulse waveform adjustment
(X PSUS, Y PSUS)
White balance adjustment
(if white balance is deviated)
VADR voltage (60V) adjustment
VSUS voltage (170V) adjustment
VOFS voltage (140V) adjustment
VRN voltage adjustment
VH voltage adjustment
DIP SW setting of the pulse value
Sustain pulse waveform adjustment
(X PSUS, Y PSUS)
White balance adjustment
Y DRIVE (A) ASSY
145