Dinel HLM-35N-SV Instruction Manual - Page 12

Browse online or download pdf Instruction Manual for Measuring Instruments Dinel HLM-35N-SV. Dinel HLM-35N-SV 20 pages. Hydrostatic level meters

Dinel HLM-35N-SV Instruction Manual
11  .  u
-
ser
adjustaBle measuring ranges
For the variants of sensors with the possibility of user settings, it is possible to choose from
the ranges shown in the following table.
User-adjustable measuring ranges for the M variant
Stainless steel diaphragm
Measuring range
0010
0035
0070
0100
0250
0400
0600
1,000
The above table defines the setting variances for each range for both stainless steel and ce-
ramic transducers. The level meters with a broad range are not recommended to be used to
measure low levels. Such usage of the sensor brings a more significant measurement error
into the measuring system.
12  .  e
xamples of markings for a Variant with user settings
HLM–35N-CV-G3/4–I–A–M–0100 kabel 3m
(N) non-explosive areas; (CV) ceramic membrane of the sensor, pressure compensation via
semi-permeable valve; (G3/4) pipe thread G ¾; (I) current (4 ... 20 mA); (A) stainless steel
cable gland for CV and SV; (M) Settings using the magnetic pen, (0100) measuring range 10,
the maximum output current can be set in the range of 5 to 10 m see table User-adjustable
measuring ranges.
HLM–35N-SK-M27–I–B–M–0070 kabel 10m
(N) non-explosive areas; (SK) stainless steel membrane of the sensor, pressure compensa-
tion by capillary; (M27) metric thread M 27x2; (I) current (4 ... 20 mA); (B) plastic threaded
cable gland, for CV, CK, SV and SK; (M) Settings using the magnetic pen, (0070) measuring
range 7 m, the maximum output current can be set in the range of 3,5 to 7 m, see table User-
adjustable measuring ranges.
12
Adjustable range
of the water column [dm]
0–10
10–35
35–70
70–100
100–250
250–400
400–600
600–1,000
Ceramic diaphragm
Measuring range
0050
0100
0200
0500
1,000
-
-
-
Adjustable range
of the water column [dm]
0–50
50–100
100–200
200–500
500–1,000
-
-
-
HLM–35