A
REA CLASSIFICATION
ULM–53N–_ _–_
ULM–53Xi–02–I
ULM–53Xi–06–I
ULM–53Xi–10–I
ULM–53Xi–20–I
17
(according to EN 60079-10 and EN 60079-14)
Performance for non-explosive areas
Explosive proof – suitable for explosive areas (combustible gases or vapours)
II 1/2G Ex ia IIB T5 with isolating repeater (IRU–420),
the whole level meter – zone 1, front head part – zone 0
Explosive proof – suitable for explosive areas (combustible gases or vapours)
II 1/2G Ex ia IIA T5 with isolating repeater (IRU–420),
the whole level meter – zone 1, front head part – zone 0
Explosive proof – suitable for explosive areas (combustible gases or vapours)
II 2G Ex ia IIA T5 with isolating repeater (IRU–420),
the whole level meter – zone 1
ULM–53