Ariston 500 STD UK Instructions For Installation Manual - Page 16

Browse online or download pdf Instructions For Installation Manual for Water Heater Ariston 500 STD UK. Ariston 500 STD UK 24 pages. Unvented hot water storage cylinders

Ariston 500 STD UK Instructions For Installation Manual
W
S
1
IRING
CHEME FOR
X
1
4
3
5
2
2
T6360B
ROOM
OR
THERMOSTAT
WHITE
5
BLUE
2
GREY
7
ORANGE
9
GREEN/YELLOW
3
V4043A
MID. POS. VALVE
BROWN
8
BLUE
2
GREY
8
ORANGE
9
GREEN/YELLOW
3
V4043H
HOT WATER VALVE
L
1
N
2
E
3
240V
MAINS INPUT (3 AMP)
Cylinder
thermostat
1
Thermal
P
cut-out
1
P
2
E
L
N
240V
MAINS INPUT (13 AMP)
F
. 2.15
IG
3 P
A
1
2 P
ORT
ND
X
ORT
A
1
B
5
CM 41
CM 51
TYPICAL
JUNCTION BOX
• 1
• 2
• 3
• 4
• 5
• 6
• 7
• 8
• 9
• 10
8
1
6
P
2
7
16
M
V
OTORISED
ALVES
Thermal
Thermostat
cut-out
L1
240V~
N
ELEMENT
3 kW 240V~