3.14
e
D
lectricAl
iAGrAMs
Should the Economy 7 system not to be used, a separate 13 amp supply to
each element will be required through a double pole fused isolating switch
having a contact gap of at least 3mm on each pole.The immersion heater
shall be installed with 85°C rubber insulated HOFR-sheathed flexible cable
complying with Table 8 of BS 6141: 1991. Make the connection(s) to the
immersion heater(s) as per F
litre models see F
Single Element
L1
N
F
. 3.13
iG
L1
N
L2
N
F
. 3.14
iG
. 3.13 and F
iG
. 3.15 (page 20).
iG
THERMAL
THERMOSTAT
CUT-OUT
THERMAL
THERMOSTAT
CUT-OUT
THERMAL
THERMOSTAT
CUT-OUT
. 3.14. For High Capacity 500
iG
ELEMENT
3 kW
240V~
DAY ELEMENT
3 kW 240V~
NIGHT ELEMENT
3 kW 240V~
ECONOMY 7