Ariston CONTRACT STD 100 Instructions For Installation Manual - Page 9
Browse online or download pdf Instructions For Installation Manual for Water Heater Ariston CONTRACT STD 100. Ariston CONTRACT STD 100 24 pages. Unvented hot water storage cylinders
Also for Ariston CONTRACT STD 100: User Manual (16 pages)
22mm COLD
MAINS IN
SERVICEABLE 3/4" PRESSURE REDUCING
CARTRIDGE AND LINE STRAINER
(SET AT 3.5 BAR)
22mm COLD
MAINS IN
F
. 2.7
IG
SERVICEABLE 1" PRESSURE REDUCING
CARTRIDGE AND LINE STRAINER
(SET AT 3.5 BAR)
28mm COLD
MAINS IN
F
. 2.8
IG
3.5
22mm BALANCED COLD WATER TAKE OFF
WITH NON-RETURN VALVE
3/4" B.S.P. CONNECTION
FOR EXPANSION VESSEL
6 BAR
15mm EXPANSION RELIEF
OUTLET TO TUNDISH
EXPANSION RELIEF VALVE
(SET AT 6 BAR)
NON-RETURN VALVE
(WITHIN HOUSING)
1" BALANCED COLD WATER TAKE OFF
WITH NON-RETURN VALVE
9
22mm TO WATER HEATER
22mm TO CYLINDER
EXPANSION RELIEF VALVE
(SET AT 6 BAR)
28mm TO
CYLINDER
3/4" B.S.P. CONNECTION
FOR EXPANSION VESSEL
For 500 litre
Models