Ariston CONTRACT STD 125 User Manual - Page 13

Browse online or download pdf User Manual for Water Heater Ariston CONTRACT STD 125. Ariston CONTRACT STD 125 16 pages. Unvented hot water storage cylinders
Also for Ariston CONTRACT STD 125: Instructions For Installation Manual (24 pages)

Ariston CONTRACT STD 125 User Manual
FIG. 10
For 300 L modles only
a) SINGLE ELEMENT
RECOMMENDED ECONOMY 7 SYSTEMS
THERMAL
CUT-OUT
L1
N
THERMAL
CUT-OUT
L2
N
THE IMMERSION HEATER SHALL BE INSTALLED WITH 85°C
RUBBER INSULATED HOFR-SHEATHED FLEXIBLE CORDS
COMPLYING WITH TABLE 8 OF BS 6141 : 1981
THE FOLLOWING DRAWING MUST BE REFERRED TO BEFORE
THE SIDE MOUNTED IMMERSION HEATER IS REPLACED.
THERMOSTAT MOUNTED
ON THE TOP
DIAG. 4A
THERMOSTAT
DAY ELEMENT
3 KW 240 V ~
THERMOSTAT
NIGHT ELEMENT
3 KW 240 V ~
ECONOMY 7
- 24 -

SCHEME OF ELECTRICAL CONNECTIONS WITH 2 MOTORISED VALVES 2 WAY

1
4
A
3
5
1
B
2
2
5
T6360B
ROOM
CM 41
OR
THERMOSTAT
CM 51
TYPICAL
BROWN
5
JUNCTION BOX
BLUE
2
• 1
GREY
1
ORANGE
10
• 2
GREEN/YELLOW
3
V4043H
HEATING VALVE
• 3
BROWN
8
• 4
BLUE
2
GREY
1
• 5
ORANGE
10
GREEN/YELLOW
3
• 6
V4043H
HOT WATER VALVE
• 7
L
1
N
2
• 8
E
3
• 9
240V
MAINS INPUT (3 AMP)
• 10
Cylinder
thermostat
1
8
1
Thermal
P
cut-out
P
6
1
P
2
Not
2
used
E
L
N
240V
MAINS INPUT (13 AMP)
FIG. 11
Thermal
Thermostat
cut-out
L1
240V~
N
- 25 -
ELEMENT
3 KW 240V~