This value defines the minimum change of humidity to cause an unsolicited report of humidity to the central
controller using Lifeline. If the value is set to 0, there will be no reports sent to the controller, when the humidity
changes. However, periodic
reports, managed by configuration parameter 18, may still be active.
0 - disabled
1-20 - value in %
18. Periodic Reports.
Parameter: 18
Size: 2 Byte
Default Value: 43200
Description:
This parameter defines the time interval to send an unsolicited report. If the value is set to 0, there will be no
periodic reports sent to the controller. However, reports on temperature/humidity changes, managed by
configuration parameters 16 and 17, may still be active.
0 - disabled
900-65535 - value in seconds
64. Temperature Scale
Parameter: 64
Size: 1 Byte
Default Value: 1
Description:
This parameter sets the temperature scale.
1 - Celsius
2 - Fahrenheit
255. Reset Parameter
Parameter: 255
Size: 4 Byte
Default Value: 0
Description:
This parameter helps reset configuration parameters and the device to factory defaults
1- Reset all Parameter settings to their default settings.
1431655765 - (0x55555555) Completely factory reset sensor and send device reset locally notification