menù impostazione - regolazione - diagnostica
descrizione
note
2 5 3 Logica spegimento
bruciatore in sanitario
2 5 4 Post-circolazione e post-
ventilazione dopo prelievo
sanitario
OFF = 3 minuti di post-circolazione e post-ventilazione dopo
un prelievo sanitario se le temperature rilevate dalla caldaia
lo richiedono.
ON = sempre attivi i 3 minuti di post-circolazione e post-
ventilazione dopo ogni prelievo sanitario.
2 5 5 Ritardo partenza in riscalda-
mento dopo prelievo
sanitario
2 5 7 Funzione Antilegionella
CLAS EVO SYSTEM - Attivo con caldaia collegata ad un
bollitore esterno con sonda NTC.
La funzione previene la formazione dei batteri della
legionella che, a volte, si sviluppano nei tubi e nei bollitori
con una temperatura compresa tra 20 e 40 °C. Se attivata,
nel caso in cui la temperatura del bollitore resti per più
di 100 ore sotto i 59 °C, la caldaia provvede a riscaldare
l'acqua del bollitore fi no a raggiungere i 65 °C per una
durata di 30 minuti.
2 5 8 Frequenza antilegionella
CLAS EVO SYSTEM
2 5 9 Temperatura obbiettivo
antilegionella
CLAS EVO SYSTEM
2 6 VERIFICA FUNZIONAMENTO COMPONENTI
2 6 0 Activation mode manuel
2 6 1 Controllo circolatore
2 6 2 Controllo ventilatore
2 6 3 Controllo valvola dev.
motorizzata
2 7 MODALITA' TEST
2 7 0 Funzione Test -
Spazzacamino
Attivabile anche premendo per 10 secondi il tasto RESET. La
funzione si disabilita dopo 10 minuti o premendo il Tasto
RESET.
2 7 1 Ciclo Disareazione
2 8 RESET MENU 2
2 8 0 Ripristino, in automatico,
delle impostazioni di
fabbrica del menu 2
Per resettare tutti i parametri alle impostazioni iniziali di
fabbrica premere il tasto OK.
range
0 = Anticalcare
0
(stop a > 67°C)
1 = Set-point +4°C
0 = OFF
0
1 = ON
da 0 a 30
0
(minuti)
0 = OFF
1 = ON
da 24 a 720 (ore)
100
da 60 a 70 (°C)
66
0 = OFF
0
1 = ON
0 = OFF
0
1 = ON
0 = OFF
0
1 = ON
0 = OFF
0
1 = ON
TEST+ =
Potenza Max Riscaldam.
TEST+
=
Potenza Max Sanitario
TEST+
=
Potenza Minima
Premere il tasto ESC
Resettare tutti
OK = Si
ESC = NO
settings - adjustment - problem identifi cation menus
description
notes
2 5 3 D.H.W. switch logic
2 5 4 Post-circulation and post-
ventilation after domestic
hot water is drawn
OFF = 3 minutes post-circulation and post-ventilation
after domestic hot water draw-off if the boiler temperature
measured requires it.
ON = always on for 3 minutes post-circulation and post-
ventilation after domestic hot water draw-off .
2 5 5 Delay start in Central
Heating after D.H.W.
request
2 5 7 Anti-legionella Function
CLAS EVO SYSTEM - Activated with the boiler connected to a
tank by an NTC sensor
This function prevents the formation of Legionnaire's
disease bacteria which may develop in the piping and
indirect cylinders at temperatures between 20°C and 40°C.
If activated, whenever the indirect cylinder temperature
stays below 59°C for over 100 hours, the boiler heats the
water in the indirect cylinder until it reaches 65°C for 30
minutes.
2 5 8 Antilegionella frequency
CLAS EVO SYSTEM
2 5 9 Antilegionella target
temperature
CLAS EVO SYSTEM
2 6 BOILER MANUAL SETTINGS
2 6 0 Manual mode activation
2 6 1 Boiler pump control
2 6 2 Fan control
2 6 3 Fan control
2 7 TEST & UTILITIES
2 7 0 Test mode
Enabled also by pressing for 10 seconds the Reset button.
This function is deactivated automatically after 10 minutes,
or when the RESET button is pressed.
2 7 1 Air purge Function
2 8 RESET MENU' 2
2 8 0 Reset factory settings
To reset all default parameter settings, press the OK button
value
0 = Anti-scale
0
(stop at > 67°C)
1 = At 4°C over set-
point
0 = OFF
0
1 = ON
from 0 to 30
0
(minutes)
0 = OFF
0
1 = ON
from 24 to 720
100
(Hours)
from 60 to 70 (°C)
66
0 = OFF
0
1 = ON
0 = OFF
0
1 = ON
0 = OFF
0
1 = ON
0 = OFF
0
1 = ON
TEST+ =
Max Heating power
TEST+
=
Max DHW power
TEST+
=
Minimum
power.
Press ESC button to active
Reset
OK = yes
ESC = no
37