Dini Argeo DGT1SAN Quick Start Manual - Page 11

Browse online or download pdf Quick Start Manual for Transmitter Dini Argeo DGT1SAN. Dini Argeo DGT1SAN 13 pages.

20. Modbus protocol - Calibration sequence
DESCRIPTION
1. Send command 0023 Hex
2. Set the span adjustment weight in registers 40902 and 40903 (if diffe-
rent from the one used during the last calibration)
3. Zero capture: unload the scale and write the "ACQUISITION POINT"
command (0025 Hex) into the command register (40001)
Set parameter "0" into parameter register (40002 / 40003)
4. Read the calibration status into input register (30116)
5. If acquisition is OK proceed with step 6. Otherwise check the load cell mV: they have to be stable.
6. Span capture: load the scale with span weight and write the acquisi-
tion command (0025 Hex) into the command register (40001)
Set parameter "1" into parameter register (40002 / 40003)
7. Read the calibration status into input register (see point 3)
8. If acquisition is OK proceed with step 9. Otherwise check the load cell mV: they have to be stable and greater then zero point.
9. Store calibration using the write calibration command (0024 Hex)
10. Wait for calibration OK status in register 30116
NOTES:
While write calibration command is in progress, some Modbus reading timeout may happen because of the saving procedure
To abort the calibration underway use 0026 Hex command in register 40001
EXAMPLE
1
(MSB)
2
1
(MSB)
2
3
4
1
(MSB)
2
.
1
(MSB)
2
3
4
1
(MSB)
00 Hex 00 Hex
00 Hex 01 Hex
00 Hex 02 Hex
00 Hex 03 Hex
00 Hex 04 Hex
00 Hex 05 Hex
1
(MSB)
2
1
(MSB)
2
3
4
1
(MSB)
2
1
(MSB)
00 Hex 04 Hex
TECH_MAN_ENG_DGT1S_QSG
00 Hex
23 Hex
(LSB)
Weight value examples
1000
6000
15000
00 Hex
00 Hex
00 Hex
00 Hex
00 Hex
00 Hex
03 Hex
17 Hex
3A Hex
E8 Hex
70 Hex
98 Hex
(LSB)
00 Hex
25 Hex
(LSB)
00 Hex
00 Hex
00 Hex
00 Hex
(LSB)
30116
2
(LSB)
Calibration not started
Acquisition underway
Acquisition OK
Acquisition error
Calibration OK
Calibration error
00 Hex
25 Hex
(LSB)
00 Hex
00 Hex
00 Hex
01 Hex
(LSB)
00 Hex
24 Hex
(LSB)
30116
2
(LSB)
Calibration OK
350000
00 Hex
05 Hex
57 Hex
30 Hex