Aeotec Nano Dimmer Manual - Page 5

Browse online or download pdf Manual for Controller Aeotec Nano Dimmer. Aeotec Nano Dimmer 10 pages.

Setting
0 - 99
256 - 316
65536 - 65560
16777215 - 16777222
Parameter 86: Set appointment 2
Set the ON time of output load.
Size: 4 Byte, Default Value: 2293760
Setting
0 - 99
256 - 316
65536 - 65560
16777215 - 16777222
Parameter 90: Enables/disables parameter 91 and 92 below:
Enables/disables the function of parameter 91 and 92.
Size: 1 Byte, Default Value: 0
Setting
0
1
Parameter 91: Set the threshold value of wattage.
Threshold change in wattage (in terms of wattage) to induce an automatic report.
Size: 2 Byte, Default Value: 25
Setting
0 - 60000
Parameter 92: Set the threshold value of wattage.
Threshold change in wattage (in terms of percentage) to induce an automatic report.
Size: 1 Byte, Default Value: 5
Setting
0 - 100
Parameter 100: Set parameter 101-103 to default value.
Set parameter 101-103 to default value.
Size: 1 Byte, Default Value: 0
Setting
0
Parameter 101: To set which reports need to be sent in Report group 1.
To set which reports need to be sent in Report group 1.
Size: 4 Byte, Default Value: 0
Setting
1
2
4
8
Parameter 102: To set which reports need to be sent in Report group 2.
To set which reports need to be sent in Report group 2.
Size: 1 Byte, Default Value: 0
http://manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZW111
Description
The brightness level
The minute value of ON time
The hour value of ON time
The day value (Mon to Sun)
Description
The brightness level
The minute value of ON time
The hour value of ON time
The day value (Mon to Sun)
Description
Disable
Enable
Description
The thershold value range is 0 to 60000
Description
The thershold value range is 0 to 100
Description
Reset the parameter 101-103
Description
Send Meter Report of voltage (V)
Send Meter Report of current (A)
Send Meter Report of wattage (W)
Send Meter Report of energy (kWh)
30-09-2020 12:35