Ariston ecoGENUS 24 RFFI Servicing Instructions - Page 12

Browse online or download pdf Servicing Instructions for Boiler Ariston ecoGENUS 24 RFFI. Ariston ecoGENUS 24 RFFI 32 pages. Condensing type c boilers
Also for Ariston ecoGENUS 24 RFFI: User Manual (28 pages)

Ariston ecoGENUS 24 RFFI Servicing Instructions

Removing the automatic air vent

1. Unscrew valve "X" (F
2. Remove (F
. 1.38).
IG
F
. 1.37
IG
F
. 1.38
IG

Removing the main circuit flow switch

1. Release the retaining clip "Y" (F
2. Remove the main circuit flow switch.
F
. 1.40
IG
12
. 1.37);
IG
X
. 1.40);
IG
Y

Removing the diverter valve actuator

1. Unplug the electrical connector "Z" (F
2. Release the retaining clip "A1" and remove the diverter
valve actuator (F
. 1.42).
IG
F
. 1.41
IG
F
. 1.42
IG

Removing the D.H.W. flow switch

1. Release the retaining clip "B1" (F
2. Remove the D.H.W. flow switch.
F
. 1.43
IG
. 1.41);
IG
Z
A1
. 1.43);
IG
B1