Ariston EuroCombi Type C A27 MFFI Servicing Instructions - Page 19

Browse online or download pdf Servicing Instructions for Boiler Ariston EuroCombi Type C A27 MFFI. Ariston EuroCombi Type C A27 MFFI 32 pages. Type c boiler
Also for Ariston EuroCombi Type C A27 MFFI: Installation Instructions Manual (28 pages), Installation Instructions Manual (24 pages), Servicing Instructions (32 pages), Servicing Instructions (32 pages)

Ariston EuroCombi Type C A27 MFFI Servicing Instructions
B2
B2
B3
B029
N.B.
It is possible to by-pass the time clock in the event of failure by simply unplug-
ging the electrical connection from the P.C.B. (see fig. 1.48). This will revert
control of the central heating to the room stat connection on the reverse of the
control panel.
B2
B2
Fig. 1.55
B4
B3
Fig. 1.56

Removing the P.C.B.s

1. Isolate electricity;
2. Remove the front cover of the boiler;
3. Remove the inspection panel (see fig. 1.6-1.7);
5. Remove the mounting screws "B2' (see fig. 1.55);
6. Disconnect the connection cable"B3" (see fig. 1.56);
7. To remove the 24V P.C.B.: remove the electrical plug
connectors and screws "B4" (see fig. 1.57);
8. To remove the 240V P.C.B.: remove the electrical plug
connectors and screws "B5" (see fig. 1.58);
9. Replace either P.C.B. in reverse order.
B4
B4
Fig. 1.57
B5
B5
Fig. 1.58
19