Ariston EuroCombi Type C A27 MFFI Servicing Instructions - Page 21
Browse online or download pdf Servicing Instructions for Boiler Ariston EuroCombi Type C A27 MFFI. Ariston EuroCombi Type C A27 MFFI 32 pages. Type c boiler
Also for Ariston EuroCombi Type C A27 MFFI: Installation Instructions Manual (28 pages), Installation Instructions Manual (24 pages), Servicing Instructions (32 pages), Servicing Instructions (32 pages)
1) Check for air in the
system
2) Check the pressure switch
for activating pump
3) Check/replace water
gauge and refill the
the system properly
1) Turn the boiler off
and then back on
again (safety reset)
B029
Supplied By www.heating spares.co Tel. 0161 620 6677
A
DOES THE
CIRCULATION PUMP
COME ON?
YES
DOES THE
INSUFFICIENT WATER
YES
INDICATOR LIGHT COME
ON? (within
40 sec.)
NO
B
NO
POWER TO
NO
THE PUMP?
YES
1) Check to see if pump is
stuck
2) Replace circulation pump
1) Check
wiring
2) Check/replace
wire to PCB
3) Replace
power supply
PCB
4) Replace control
PCB
5) Check micro-
switch when hot
water is requested.
21