3. TIME CLOCK
403

SHUTDOWN PROCEDURE

To turn off the main burner, simply press the On/Off switch "L"; the
green L.E.D. "I" will also turn off.
As a precautionary measure, it is recommended that the gas cock
located on the bottom of the boiler be turned off as well.
Reset
Enter
switching
times
Input
Imput
time
Operating the time switch
The step marked with the symbol "
switching program.
Preparing for Operation
Activate the "Res" switch (=RESET) to reset the time switch to its
default setting (activate using a pencil or similar pointed instrument). Do
this:
- every time you wish to "reset" the time switch
- to erase all switching times and the current time of day.
After approximately two seconds the following display appears:
Enter current time and weekday
- Keep the "
" key pressed down
During the summer time period press the +/- 1h key once.
Enter the hour using the "h" key
Enter the minutes using the "m" key
Enter the day using the "Day" key
1 = "Monday"..............7 = Sunday
- Release the "
Manual switch
Day
Enter
weekday/s
" are necessary to carry out a
" key.
Summer and
winter time
setting
Enter
the hours
Week-
days
flash
Enter
minutes
UT008Am