Ariston GENUS PREMIUM EVO HP 150 Design, Installation And Servicing Instructions - Page 37

Browse online or download pdf Design, Installation And Servicing Instructions for Boiler Ariston GENUS PREMIUM EVO HP 150. Ariston GENUS PREMIUM EVO HP 150 44 pages. Wall-hung condensing gas boiler hp
Also for Ariston GENUS PREMIUM EVO HP 150: User Manual (17 pages), User Manual (24 pages)

Ariston GENUS PREMIUM EVO HP 150 Design, Installation And Servicing Instructions
description
notes
8. 2 BOILER
8. 2. 1 Fan Status
8. 2. 2 Fan Speed - x100 RPM
8. 2. 3 Aperto
8. 2. 4 Diverter valve position
8. 2. 5 D.H.W. Flow Rate (l/min)
8. 2. 7 Pump Modulation (%)
8. 2. 8 Gas Power (kW)
8. 3 BOILER TEMPERTURE
8. 3. 0 Set temperature Central Heating(°C)
8. 3. 1 Flow Heating temperature (°C)
8. 3. 2 Return Heating temperature (°C)
8. 3. 3 Domestic Hot Water Temperature (°)
8. 3. 5 Outdoor temperature (%)
Only with external sensor connected
8. 4 SOLAR & STORAGE
8. 4. 0 Storage Measured Temperature (°C)
8. 4. 2 D.H.W. Inlet Temperature (°C)
Display only with Solar Kit or external storage Kit
8. 5 SERVICE
8. 5. 0 Months to next
maintenance
If setted the boiler will display that is time to call the
installer for maintenance
ALERT
8. 5. 1 Enable Maintenance
advice
8. 5. 2 Maintenance Warning
Reset
to erase the advice for maintenance
8. 5. 4 P.C.B Hardware version
8. 5. 5 P.C.B Software version
8. 6 ERROR HISTORY
8. 6. 0 Last 10 errors
This parameter makes it possible to see the last 10 errors
shown by the boiler as well as the relevant day, month
and year.
Turning the encoder allows for viewing the sequence of
errors that occurred, from 0 to 9.
8.6.0 Last 10 errors
8. 6. 1 Reset Error List
value
0 = OFF
1 = ON
0 = D.H.W.
1 = Central Heating
from 0 to 60
(month)
Warning 3P9
Sched.Maintanace-Call Service
0 = OFF
0
1 =ON
Reset? OK= Yes Esc
= No
from Error 0 to Error 9
Fault 3
No flame detected
501
12:18 24/01/2012
Reset?
Ok=Yes
Esc=No
24
technical area
37