Ariston INTESA TP30 User Manual, Installation & Servicing Instructions - Page 20

Browse online or download pdf User Manual, Installation & Servicing Instructions for Boiler Ariston INTESA TP30. Ariston INTESA TP30 50 pages.

Installation

6.12 Fitting the Time Clock

To fit the mechanical time clock supplied with the boiler, it is nec-
essary to proceed as follows:
1) Remove the fastening screws 'A' from beneath the boiler;
2) Rotate the control panel forward, if necessary, it is possible to
lift the control panel up and rotate it to a fully horizontal posi-
tion;
3) Using a suitable knife, remove the knock out 'B' for the time
clock;
4) Insert the clock into the control panel;
5) Secure the clock in place using the four screw provided;
6) Remove the two screws 'C' and remove the cover to allow
access to the Printed Circuit Board;
7) Plug the clock cable into the connector on the Printed Circuit
Board and conect the cables to the clock as indicated in Fig.
6.21
1
A
2
3
Supplied By www.heating spares.co Tel. 0161 620 6677
A
B
20
4
5
6