Aeotec 7 Pro ZWA012 User Manual - Page 12

Browse online or download pdf User Manual for Security Sensors Aeotec 7 Pro ZWA012. Aeotec 7 Pro ZWA012 14 pages. Door / window sensor

Aeotec Door/Windows Sensor 7 Pro User guide : Aeotec Help Desk
0 -
Time set in seconds
32400
Parameter 11: Time Delay of OFF command from Group #2.
The time period after which the OFF command frame will be sent.
Size: 2 Byte, Default Value: 0
Setting Description
0 -
Time in seconds
32400
Parameter 12: Delay of tamper alarm cancellation.
The time period after which a tamper alarm will be canceled.
Size: 2 Byte, Default Value: 0
Setting Description
0 -
Time in seconds
32400
Parameter 13: Reporting tamper alarm cancellation.
Reporting cancellation of tamper alarm to the controller and 3rd Association Group.
Size: 1 Byte, Default Value: 1
Setting Description
0
do not send tamper cancellation report
1
send tamper cancellation report
Parameter 14: Central Scene Event Functionality
This parameter enables/disables the central scene function.
Size: 1 Byte, Default Value: 0
Setting Description
0
Disabled
1
Enable
Parameter 15: Tilt Sensor Functionality
This parameter enables/disables the tilt function.
Size: 1 Byte, Default Value: 1
Setting Description
0
Disabled
1
Enable
Parameter 16: Tilt Sensor State
This parameter allows to set in what state is door/window when the tilt is in an OFF state.
12 z 14
https://aeotec.freshdesk.com/support/solutions/articles/6000230465
23. 2. 2021, 19:15