Ariston MB 91 AUS Instructions For Installation And Use Manual - Page 11

Browse online or download pdf Instructions For Installation And Use Manual for Oven Ariston MB 91 AUS. Ariston MB 91 AUS 13 pages. Maxioven

Ariston MB 91 AUS Instructions For Installation And Use Manual
Important: The power supply to the appliance must be
cut off before any adjustments or maintenance work is
done on it.
Installation of Built-in Ovens
To ensure the proper working order of the built-in
appliance, the kitchen unit must be of a suitable size.
The sizes of the unit for installing the cooker under a
worktop or in a column unit are shown in figure.
min. 45 mm.
To provide adequate ventilation, there must be appropriate
ventilation openings in the front bottom and the top part of
the cabinet (an intake opening on the bottom of at least
200 cm
2
, and an exhaust opening of at least 60 cm
The unit panels next to the cooker must be heat resistant.
In the case of veneered wood units, glues must be resistant
to a temperature of 120 °C.
In accordance with safety standards, once the appliance
has been mounted, there must be no possible contact
with electrical parts. Any protective parts must be secured
so that they can only be removed with the use of tools.
Fastening the oven
Insert the appliance into the compartment; open the
oven door and fasten the oven to the cabinet using
the four screws "A", remembering to place the special
spacers provided between the hole and the screw
itself.
Electric connection
Cookers with a three-pole power supply cable are
designed to operate with alternated current at the supply
frequency and voltage indicated on the data plate (at the
bottom of the oven dashboard). The earthing conductor
of the cable is the yellow-green conductor.

Installation

Connecting the power supply cable to the mains
The appliance must be directly connected to the mains
using an omnipolar circuit-breaker with a minimum
contact opening of 3 mm installed between the appliance
and the mains, suitable for the load indicated and
complying with current directives (the earthing wire must
not be interrupted by the circuit-breaker).
The power supply cable must be positioned so that it does
not exceed 50°C more than room temperature at any point
of its length.
Before making the connection check that:
the limiter valve and the home system can support the
appliance load (see data plate);
the power supply system has an efficient earthing
connection which complies with the provisions of
current regulations;
the socket or omnipoar circuit-breaker is easily
accessible once the cooker has been installed.
NOTE: do not use reducers, adaptors or shunts as they
could cause overheating and burns.
A
2)
.
A

Technical Specifications

Oven size
width
depth
Height
Powers supply:
- Static oven:
- Lower heating element:
- Upper heating element:
- Grill:
- Maxigrill:
- Ventilated Maxigrill:
- Gentle pastry oven:
- Ventilated oven:
Electric oven size:
Voltage end frequency:
Power supply Max:
10
250
200
45
30
F
A
240V
2550W
1400W
1150W
2200W
3350W
3350W
1400W
3050W
230-240V / 50Hz
3400W(240V)- 3100W(230V)
A
50
100
150
15
A
cm. 54
cm. 38
cm. 33
230V
2350W
1300W
1050W
2000W
3050W
3050W
1300W
2800W
litres 68