AEP MP2x8i NMEA Buffer Installation And User Manual - Page 5

Browse online or download pdf Installation And User Manual for Marine Equipment AEP MP2x8i NMEA Buffer. AEP MP2x8i NMEA Buffer 9 pages. Buffer
Also for AEP MP2x8i NMEA Buffer: Installation And User Manual (2 pages)

AEP MP2x8i NMEA Buffer Installation And User Manual
3

Terminal description

Power and signal connection for hardware rev_1.0 and higher.
SW1: DIP Switch. Configuration switch is used to configure the working mode of the NMEA Buffer. SW1‐1 ON set Single Input
Transmission with auto switching and SW1‐1 OFF set dual Dual Independent Transmission. SW1‐2 is not used in this application.
X1: Power and NMEA input connection
1.
PWR + power positive
2.
PWR – power negative
3.
Grounding
4.
NMEA1 + input 1
5.
NMEA1 – input 1
6.
Grounding
7.
NMEA1 + input2
8.
NMEA1 – input 2
X2: Outputs connection
1.
NMEA out 1 A
2.
NMEA out 1 B
3.
NMEA out 2 A
4.
NMEA out 2 B
5.
NMEA out 3 A
6.
NMEA out 3 B
7.
NMEA out 4 A
8.
NMEA out 4 B
X3: Outputs connection
1.
NMEA out 5 A
2.
NMEA out 5 B
3.
NMEA out 6 A
4.
NMEA out 6 B
5.
NMEA out 7 A
6.
NMEA out 7 B
7.
NMEA out 8 A
8.
NMEA out 8 B
Table 1: Terminal description.