INJECTORS TABLE
Type of gas used
Type of burner
Rapid
NATURAL GAS
Semi-rapid
G20
(Methane)
Auxiliary
LIQUEFIED
Rapid
PETROLEUM GAS
Semi-rapid
G30
(Butane)
Auxiliary
LIQUEFIED
Rapid
PETROLEUM GAS
Semi-rapid
(Propane)
G31
Auxiliary
Type of gas used
G20 20 mbar
G30 28-30 mbar
G31 37 mbar
ELECTRIC SUPPLY: 220-240 V ~ 50-60 Hz - 0,6 W
Injector
marking
115 Y
95 Z
72 X
85
68
50
85
68
50
Model con guration
Rated thermal owrate
4 BURNERS
1R - 2SR - 1AUX
1R - 2SR - 1AUX
1R - 2SR - 1AUX
Rated thermal
Rated
ow rate
consumption
kW
3,00
286 l/h
1,75
167 l/h
1,00
95 l/h
3,00
218 g/h
1,75
127 g/h
1,00
73 g/h
3,00
214 g/h
1,75
125 g/h
1,00
71 g/h
(kW)
7,50
7,50
7,50
CATEGORY II2H3+
Reduced heat
capacity
kW
min.
0,70
0,40
17
0,40
0,70
0,40
20
0,40
0,70
0,40
25
0,40
Total rated
Air required (m
consumption
714 l/h
545 g/h
536 g/h
Gas pressure
mbar
rat.
max.
20
25
28-30
35
37
45
) for burning
3
1m
of gas
3
9,52
30,94
23,80