Table 1
Burner
Semi Fast (S)
Auxiliary (A)
Triple Crown (TC)
Semi-Fishburner (SP)
Double flame (DCDR internal)
Double flame (DCDR external)
2 nozzle
Supply
Pressures
*
At 15°C and 1013 mbar-dry gas
**
Propane
P.C.S. = 50,37 MJ/kg
***
Butane
P.C.S. = 49,47 MJ/kg
Naturale
P.C.S. = 37,78 MJ/m
This appliance conforms with the following European
Economic Community directives:
-
73/23/EEC of 19/02/73 (Low Voltage) and subsequent
modifications;
-
89/336/EEC
of
03/05/89
Compatibility) and subsequent modifications;
-
90/396/EEC of 29/06/90 (Gas) and subsequent
modifications;
-
93/68/EEC of 22/07/93 and subsequent modifications.
Burners and Nozzle Specifications
Diameter
Thermal power
(mm)
kW (p.c.s.*)
Nomin.
Ridot.
75
1,90
0,40
55
1,00
0,40
130
3.25
1.30
—
1,50
0,70
30
0,90
0,40
130
4,10
1,30
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
3
(Electromagnetic
Liquid Gas
By-Pass
Nozzle
1/100
1/100
(mm)
(mm)
***
30
70
138
30
50
73
57
91
236
41
60
109
30
44
65
57
70
298
28-30
20
35
PH 760 RF GH
PH 750 RT GH
PH 741 RQO GH
21
Natural Gas
Flow*
Nozzle
g/h
1/100
**
(mm)
136
106
71
79
232
133
107
88
64
70
293
114
37
20
25
17
45
25
A
PH 760 RF
A
A
Flow*
l/h
181
95
309
143
86
390