Ariston PH 941MSTV Operating Instructions Manual - Page 5

Browse online or download pdf Operating Instructions Manual for Hob Ariston PH 941MSTV. Ariston PH 941MSTV 13 pages. Built-in cooking table
Also for Ariston PH 941MSTV: Instructions For Installation And Use Manual (13 pages), Specifications (13 pages), Installation And Use Manual (34 pages), Operating Instructions Manual (20 pages)

Ariston PH 941MSTV Operating Instructions Manual

Burner and nozzle specifications

Table 1
Burner
Fast (Large) (R)
Reduced Fast (RR)
Semi Fast (Medium) (S)
Auxiliary (Small) (A)
Triple Crown (TC)
Semi-FishBurner (SP)
Supply
pressures
*
At 15°C and 1013 mbar - dry gas
**
Propane P.C.S. = 50.37 MJ/Kg
Table 1 (For Hungary)
Burner
Fast (R)
Reduced Fast (RR)
Semi Fast (Medium) (S)
Auxiliary (Small) (A)
Triple Crown (TC)
Semi-FishBurner (SP)
Supply pressures
At 15°C and 1013 mbar-dry gas
P.C.I. G20
35,9 MJ/m
S
A
S
R
PH 941 MS
S
A
TC
RR
PH 941 MSTB
PH 941 MSTB GH
! The hob can only be installed above built-in ovens with a cooling ventilation system.
Diameter
Thermal Power
(mm)
kW (p.c.s.*)
Nom.
Red.
100
3.00
0.70
100
2.60
0.70
75
1.65
0.40
55
1.00
0.40
130
3.25
1.50
-
1.50
0.70
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
G 20
Thermal
Power kW
1/100 (mm)
2,90
2,45
1,60
0,90
3,15
1,50
25 mbar
P.C.I. G30
3
P.C.I. G25.1
S
A
RR
TC
PH 941 MSTV
PH 941 MSTV GH
S
A
TC
RR
SP
PH 960 MST
PH 960 MST GH
Liquid Gas
By-pass
Nozzle
1/100
1/100
(mm)
(1)
(mm)
41
39
86
41
39
80
30
28
64
30
28
50
60
61
91
41
39
60
***
Butane P.C.S. = 49.47 MJ/Kg
Natural P.C.S. = 37.78 MJ/m
G 25.1
Nozzle
Thermal
Nozzle
Power kW
1/100 (mm)
116
2,25
116
110
1,90
110
96
1,25
71
0,65
133
2,45
133
88
1,15
25 mbar
3
122,8 MJ/m
3
30,9 MJ/m
S
TC
PH 930 MST
S
A
TC
PH 940 MST
Naturale Gas
Flow*
Nozzle
Flow*
g/h
1/100
***
**
(mm)
218
214
116
286
189
186
110
248
120
118
96
157
73
71
71
236
232
133
309
109
107
88
143
28-30
37
20
20
25
17
35
45
25
3
G 30
Thermal
Nozzle
Power kW
1/100 (mm)
2,70
86
2,30
80
96
1,50
64
71
0,90
50
2,90
91
88
1,40
60
30 mbar
TC
RR
GB
l/h
95
5