Ariston PKQ 755D GH LPG Operating Instructions Manual - Page 12

Browse online or download pdf Operating Instructions Manual for Hob Ariston PKQ 755D GH LPG. Ariston PKQ 755D GH LPG 45 pages.

Ariston PKQ 755D GH LPG Operating Instructions Manual
Adapting to G30 gas
GB
! This procedure must be performed by a qualified
technician authorised by the manufacturer.
! Once this procedure is finished, replace the old rating
sticker with one indicating the new type of gas used. Stickers
are available from any of our Service Centres.
! Should the gas pressure used be different (or vary slightly)
from the recommended pressure, a suitable pressure
regulator must be fitted to the inlet pipe )in order to comply
with current national regulations).

Burner and nozzle specifications

Table 1
Burner
Fast (R)
Semi Fast (S)
Auxiliary (A)
Supply pressures
*
At 15°C and 1013,25 mbar-dry gas
**
Propane
***
Butane
S
S
A
PK 644 D GH X LPG
12
Diameter
Thermal Power
(mm)
kW (p.c.s.*)
Nomin.
Reduc.
157
2.60
1.00
132
1.75
0.80
110
0.90
0.50
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
P.C.S. = 50.37 MJ/Kg
P.C.S. = 49.47 MJ/Kg
S
R
R
A
PK 755 D GH X LPG
PKQ 755 D GH LPG
DATA PLATE
Electrical
see data plate
connections
This appliance conforms to the following
European Economic Community directives:
- 2006/95/EEC dated 12/12/06 (Low
Voltage) and subsequent amendments
- 2004/108/EEC dated 15/12/04
(Electromagnetic Compatibility) and
subsequent amendments
- 93/68/EEC dated 22/07/93 and
subsequent amendments.
- 2009/142/EEC dated 30/11/09 (Gas) and
subsequent amendments.
- 2012/19/EC and subsequent
amendments.
Liquid Gas
Adjusting the
G31**
burner's primary
Nozzle
Flow*
By-pass
1/100
1/100
g/h
(mm)
(mm)
52
80
186
45
65
125
35
48
64
37
25
44
S
A
Liquid Gas
G30***
burner's primary
air G31
Nozzle
Flow*
1/100
g/h
(mm)
(mm)
3,70
80
189
2,60
65
127
2,20
48
65
28-30
25
35
Adjusting the
air G31
(mm)
7,10
4,00
3,50