Whirlpool 6ED22DQXFB01 Service Manual - Page 6
Browse online or download pdf Service Manual for Refrigerator Whirlpool 6ED22DQXFB01. Whirlpool 6ED22DQXFB01 36 pages. Side by side
WHIRLPOOL CONSUMER SERVICES
Models 6ED22DQXFW00 6ED22DQXFB01 6ED22DQXFW01
MODULAR ICEMAKER SERVICE
Specifications
Mould Heater
Thermostat
Water Fill
Motor
Module
Module Test Points
V
L
Module Ohmmeter Checks
Power to icemaker and ejector blades in park
position)
Test
Compo-
Module Position
Points
nent
L-H
Mould
Attached to
Heater
support
L-M
Motor
Disconnected
from support
Test
Compo-
Line Voltage
Points
nent
L - N
Module
Power OK
T - H
Bi-metal
Open
L - H
Heater
On
L - M
Motor
On
N - V
Water
On
valve
Service Procedures
Cover
Prise plastic pin from right hand side of module
and remove cover.
Module, Motor and Support Assembly
: 185 W, 286 ohms
-8 ± 1.5°C
: Close
0 ± 1.5°C
Open
: 140 ml, 7.5 seconds
: 3 Watts, 16900 Ohms
: Stamped circuit, plug-
in connections
N
M
Remove 3
securing
screws
H
T
(No
Resist.
Ohms
286
16900
0 Volts
No
power
Closed
Off
Off
Off
6ED22DQXFB02 6ED22DQXFW02
6ED22DQXFB03 6ED22DQXFW03
Insert phillips head screwdriver in access ports
in module and remove both screws. Disconnect
shut-off, pull mould from support assembly
Shut-off Arm
Pull out from support. When reassembling
insert to full depth.
Mould and Heater
Remove module, motor and support assembly.
Bi-metal
Remove module and support assembly. Pull
out retaining clips with bi-metal.
Fill Cup
Remove motor, module and support assembly,
remove ejector blades and shut-off arm. Pull
cup from mould.
Ejector Blades and Stripper
Remove module, motor, support assembly.
When reinstalling ejector blades, align "D"
coupling with module cam.
Water Level Adjustment
Turning the screw clockwise decreases the
water fill.
• 1/2 turn equals 20 ml or 1.2 seconds
• full turn equals 40 ml or 2.4 seconds
• Maximum adjustment is one full turn in
either direction. Additional rotation could
damage the module.
Page 6 of 36