Whirlpool 27' Installation Instructions Manual - Page 7

Browse online or download pdf Installation Instructions Manual for Dryer Whirlpool 27'. Whirlpool 27' 48 pages. Microwave oven and thermal oven
Also for Whirlpool 27': Job Aid (36 pages), Installation Instructions Manual (11 pages), Installation Instructions Manual (11 pages), Installation Instructions Manual (22 pages), Installation Instructions Manual (27 pages), Installation Instructions Manual (32 pages), Installation Instructions Manual (12 pages), Installation Instructions (5 pages)

Whirlpool 27' Installation Instructions Manual
Installation Spacing
14"* max.
(356 mm)
5
/
"*
1
2
(140 mm)
1"*
(25 mm)
*Required spacing
3"*
(76 mm)
48 in.
(310 cm
18"*
(457 mm)
24 in.
(155 cm
1"*
(25 mm)
3"*
(76 mm)
Installation spacing for recessed area
or closet
The dimensions shown are for the minimum spacing allowed.
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door, and
floor moldings.
Additional spacing of 1" (25 mm) on all sides of the dryer is
2
*
recommended to reduce noise transfer.
2
)
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Companion appliance spacing should also be considered.
Mobile home – Additional installation
2
*
requirements
2
)
This dryer is suitable for mobile home installations. The
installation must conform to the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280) or the Canadian
Manufactured Home Standard CAN/CSA-Z240 MH.
Metal exhaust system hardware, available for purchase.
For further information, please reference the "Assistance
or Service" section of the "Use and Care Guide."
Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such
as a nearby window) should be at least twice as large
as the dryer exhaust opening.
7