Whirlpool 3LCED9100 Installation Instructions Manual - Page 4

Browse online or download pdf Installation Instructions Manual for Dryer Whirlpool 3LCED9100. Whirlpool 3LCED9100 48 pages. Commercial he dryer
Also for Whirlpool 3LCED9100: Installation Instructions Manual (48 pages), User Instructions (5 pages)

Whirlpool 3LCED9100 Installation Instructions Manual

Tools and Parts

Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools
listed here.
Tools needed:
200 mm (8") or 250 mm
I
(10") Pipe wrench
200 mm (8") or 250 mm
I
(10") Adjustable wrench
Flat-blade screwdriver
I
Phillips screwdriver
I
Adjustable wrench that
I
opens to 25 mm (1") or
hex-head socket wrench
Level
I

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.
I Check code requirements: Some codes limit or do not permit
installation of clothes dryers in garages, closets, or sleeping
quarters. Contact your local building inspector.
I Do not install on carpet.
NOTE: The dryer must not be installed in an area where it will be
exposed to water and/or weather.
Recessed Area and Closet Installation Instructions
This dryer may be installed in a recessed area or closet. This
dryer must not be installed behind a lockable door, a sliding door,
or a door with a hinge on the opposite side to that of the dryer.
The installation spacing is in millimeters and is the minimum
allowable. Additional spacing should be considered for ease
of installation, servicing, and compliance with local codes
and ordinances.
4

INSTALLATION REQUIREMENTS

8 mm (
5
") socket wrench
I
16
Utility knife
I
Vent clamps
I
Sealing compound gun
I
and sealing compound (for
installing new exhaust vent)
Pliers
I
Stiff-bladed putty knife
I
Parts supplied:
Remove parts bag from dryer drum. Check that all parts were
included.
Foot boot (4)
I
NOTE: The circuit diagram for this dryer is located inside the
lower front panel, within the Tech Sheets.
Technical
Specifications:
220 – 240 V, 50 Hz. AC
4575W
Total mass: 68 kg max.
NOISE: Sound Pressure Level, Lpa: 58 dBA (uncertainty, Kpa:
+/–10 dBA).
If installed in a closet with a door, the minimum unobstructed air
opening in the top and bottom is required. Louvered doors
with equivalent air openings are acceptable.
The dryer must be exhausted outdoors.
No other fuel-burning appliance may be installed in the same
closet as the dryer.
Minimum Installation Clearances
381 mm
(15")
0 mm
0 mm
(0")
(0")
Recessed front view
Additional clearances for wall, door, and floor moldings may be required or if
external exhaust elbow is used.
*
2
310cm
2
)
(48 in.
closet
Front
door
view
*
2
155cm
2
(24 in.
)
Dryer foot (4)
I
Clothes Capacity:
9 Kg Max.
356 mm
(14") max
Closet
door
25 mm (1")
Closet side view
76 mm (3")
*Opening is the minimum
for a closet door. Louvered
doors with equivalent air
openings are acceptable.
76 mm (3")
0 mm
(0")