Exhaust hoods:
Must be at least 305 mm (12") from ground or any object
n
that may obstruct exhaust (such as flowers, rocks, bushes,
or snow).
Recommended Styles:
Louvered hood
Acceptable Style:
Angled hood
Elbows:
45° elbows provide better airflow than 90° elbows.
n
Good
Clamps:
Use clamps to seal all joints.
n
Exhaust vent must not be connected or secured with screws
n
or other fastening devices that extend into interior of duct
and catch lint. Do not use duct tape.
See "Venting Kits" for more information.
Box hood
Better
Plan Vent System
Recommended exhaust installations
Typical installations vent the dryer from the rear of the dryer.
Other installations are possible.
A
A. Dryer
F. Rigid metal or flexible metal vent
B. Elbow
G. Vent length necessary to connect elbows
C. Wall
H. Exhaust outlet
D. Exhaust hood
I. Optional side exhaust outlet
E. Clamps
Standard rear offset exhaust installation