Whirlpool Centennial MEDC700 Installation Instructions Manual - Page 6
Browse online or download pdf Installation Instructions Manual for Dryer Whirlpool Centennial MEDC700. Whirlpool Centennial MEDC700 16 pages. 27" wide models - u.s.a. only
Power Supply Cord
WARNING
use a new ul listed 30 amp power supply cord.
use a ul listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal (silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
Electrical Connection options
If your home has:
4-wire receptacle (NEMA
Type 14-30R)
3-wire receptacle (NEMA
type 10-30R)
4-wire direct
3-wire direct
*If local codes do not permit the connection of a cabinet-ground
conductor to the neutral wire, go to "Optional 3-wire connection"
section.
6
Electrical Connection
Fire Hazard
And you will be
Go to
connecting to:
Section:
A UL listed, 120/240-
4-wire
volt minimum, 30-
connection:
amp, dryer power
Power
supply cord*
supply cord
A UL listed, 120/240-
3-wire
volt minimum, 30-
connection:
amp, dryer power
Power
supply cord*
supply cord
A fused disconnect
4-wire
or circuit breaker
connection:
box*
Direct Wire
A fused disconnect
3-wire
or circuit breaker
connection:
box*
Direct Wire
Direct Wire
WARNING
Use 10 gauge solid copper wire.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal (silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
1. Disconnect power.
2. Remove the hold-down screw (D) and terminal block
cover (A).
C
B
A. Terminal block cover
B. External ground conductor screw
C. Center, silver-colored terminal block screw
D. Hold-down screw
E. Neutral ground wire
F. Hole below terminal block cover
Fire Hazard
E
F
A
D